40-400-00022 Rev. B
35
7
Press ENTER several times to bring up the Main Menu.
8
Enter 87 to upgrade the FLASH EEPROM CONFIGURATION
9
Enter 0 to Download program to Flash Memory
10 Enter Y if you are sure
11 Select Transfer or ALT+T to transfer the new program
12 Select Send Text File or T to send file
13 Select file DS100V20.txt (remember where you stored it?)
During the transmission of the upgrade file, a series of dots will scroll across
the screen, feedback from the DS-100 Data Switch that the upgrade is going
smoothly. If the upgrade fails after the first few dots appear, go back and
reset the Line delay to 300 milliseconds.
If you could see the front panel of the DS-100, you would see the Power and
Ports LED’s blinking during the upgrade. The upgrade should take about 5-6
minutes, hit <ESC> to start the DS-100 with the upgrade when the message
appears. If you wait longer than 60 seconds, the DS-100 will start the
upgrade by itself.
You have now completed the upgrade.
The final menu item is 99, which is used to exit the programming mode.
Forced exit will occur if the Programming Inactivity Time-out expires, see
menu item 23.
Select entry > 99
Exiting Menu
If you experience any difficulty in with this process, contact Teltone's Techni-
cal Support Department.