30
40-400-00022 Rev. B
PORT TEST
Connect cable between Modem port and the User port to be tested,
then select port.
Enter <ESC> to abort test at any time.
Select Port (1-8):
Use a standard RS-232 cable (9 pin female - 9 pin male) and connect the
Modem port to a User port to test. All leads will be tested along with the
Transmit and Receive connections (at a 57.6 Kilobit rate).
Select entry > 86
CONNECT TO MODEM PORT
The Local Maintenance port is being connected to the Modem port.
All characters received at the Local Maintenance port will be echoed to
the Modem port, and all characters received at the Modem port will be
echoed to the local port.
Terminate by sending <ESC><ESC><ESC> (within 2 seconds) to the
local port.
5.
RESET UNIT TO DEFAULTS
Select entry > 5
Reset Unit to Default Configuration
0 Factory Defaults
1 User Defaults
Select Option: 0
Reset Unit to Factory Defaults
ARE YOU SURE? (Y/N)
n
Unit NOT Reset to Defaults
If you answer Y (YES) to this programming option (0 Factory Defaults), the
default values for all programmable settings will be reset to the original
Factory Default settings. The system report shown earlier displays all of the
Factory Default settings.
Select entry > 5
Reset Unit to Default Configuration
0 Factory Defaults
1 User Defaults
Select Option: 1
Reset Unit to User Defaults
ARE YOU SURE? (Y/N)
y
Unit Reset to Defaults
6.
SAVE ACTIVE CONFIGURATION AS USER DEFAULTS
Select entry > 6
Save Active Configuration As User Defaults
ARE YOU SURE? (Y/N) y
Active Configuration Saved As User Default
Any changes made during programming will be saved in non-volatile