Connect the cable
•
Remove the sealing cable gland plug from the gland nut.
•
Open the sealing gland nut and remove it. Don not disassembles the gland base from
the bracket.
•
Insert the cable into the sealing gland base and connect it to the RJ-45 connector at the
bottom of the CPE. Make sure the connector is completely inserted and tightened.
•
Insert the rubber bushing on the cable into the gland base.
•
Tighten the gland nut. Use the dedicated tool for fastening the sealing glands.
3.
Seal the connector
•
Attach the mastic tape (Scotchfil
TM
Electrical Insulation Putty) and wrap it around the
connector butting up against the connector. Do not over stretch.
•
Squeeze to tighten the mastic sealer. Make sure there are no air bubbles.
•
Slide the cold shrink sleeve on top of the connector. Make sure that the sleeve covers
both cable connector and unit connector.
•
Pull the cord slowly to shrink the sleeve.