Page 7 of 33
2 Operator Information
2.1 Printer Top View
Printer Status LED
LED
PRINTER STATUS
Solid Green
Printer Ready
Flashing Green and Red
Printer Platen in Open
Position, or Paper Out of
Mechanism
Solid Red
Paper Roll Low
2.3 Primary AC Power Input
The power module is where the main power fuses are located. In this module, the primary power may be set to
115 VAC or 230 VAC. To change the primary AC input voltage, or replace a fuse, perform the following:
1. To gain access to the primary power fuse location, use a small flat blade screw driver to pry open the
access door at the pry point as shown below.
2. Remove the fuse module by using a small flat blade screw driver to pry up on the edge of the fuse module.
The fuse module will pull straight out of the AC input module.
3. Once the fuse module is out of the unit, replace the fuse with a proper rating fuse if necessary, or change
the voltage by rotating the fuse module 180°. Reinstall the fuse module into the AC receptacle with the desired
voltage positioned for display in the view window. The voltage selected can be seen by looking at the voltage
displayed in the view window located on the right side of the module when the access door is closed.
Figure 2 SP-5000 Fuse Module
F1 = 2A/250V for 115 VAC operation
F2 = 1A/250V for 230 VAC operation
Figure 3 SP-5000 Back View