Page 11 of 33
4 Interface Specifications
4.1 Serial Interface Specifications
The SP-5000 can be used as either a serial or parallel device. The serial interface parameters are set via SW1 and
SW2. Baud rate, serial parameters and KIOSK options are set with SW1. SW2 is used to set the specific serial
interface configuration.
4.1.1 SW1 Switch Settings
1 2 3 4 5 6 7 8
Baud Rate Stop Parity Data Parity Delivery
Bits Length Odd/ System
Even
Setting
600 Close Open Open
1,200 Open Close Open
2,400 Close Close Open
4,800 Open Open Close
9,600 Close Open Close
19,200 Open Close Close
38,400 Close Close Close
115,200 Open Open Open
1 Close
2 Open
Disable Close
Enable Open
7 Bits Close
8 Bits Open
Even Close
Odd Open
Disable Close
Enable Open
Switches SW1 and SW2 are located on the printer’s main controller board. See next page for switch locations.