56050301 – Rev B
12
© 2017 Telguard
If LED 1 and LED 4 are flashing, the Telguard has failed activation. The serial number is
not in the database at the TCC. Clear the fault (see note below) and call Telguard
Technical Support to verify proper registration before resending an alarm signal.
If LEDs 1-5 are flashing, there is an activation error. The activation message was NOT
received at the TCC. Clear the fault (see note below) and retry transmitting an alarm signal.
If Telguard fails a second time to activate, check signal strength. If signal strength is OK,
then call Telguard Technical Support for further assistance.
NOTE: In order to clear the faults listed above, the RSSI button must be pressed twice.
After the issue has been resolved and the unit cleared, STEPS 3 AND 4 MUST BE
REPEATED OR THE TELGUARD WILL NOT TRANSMIT ANY SIGNALS.