![Telephonics Trulink User Manual Download Page 43](http://html1.mh-extra.com/html/telephonics/trulink/trulink_user-manual_1082113043.webp)
T
E L E P H O N I C S
C
O R P O R A T I O N
TM115007 REV A (04/07)
5-3
USE OR DISCLOSURE OF DATA CONTAINED ON THIS PAGE IS SUBJECT TO THE
RESTRICTION ON THE TITLE PAGE OF THIS DOCUMENT
.
C
O M M U N I C A T I O N
S
Y S T E M S
D
I V I S I O N
Table 5.3-1
Charge LED Indication
CURRENT STATUS
RED LED
GREEN LED
No Radio
OFF
OFF
Error including TPT with non-
rechargeable batteries
FLASHING 50%
OFF
Charging
OFF
FLASHING 50%
Fully charged
OFF
ON
Radio detected, but charge status
from battery not yet updated
FLASHING 50%
FLASHING 50%
5.4 BIT
INDICATION
The display overlay consists of two LEDs (red and green) for BIT indication at each TPT plug-in
bracket. The BIT LED indications are shown Table 5.4-1.
Table 5.4-1
BIT LED Indications
CURRENT STATUS
RED LED
GREEN LED
No Radio
OFF
OFF
Error
FLASHING 50%
OFF
Performing BIT
OFF
FLASHING 50%
BIT OK
OFF
ON
Setting of Channel
FLASHING 50%
FLASHING 50%
5.5
TPT CHANNEL SELECTION
This procedure will set the channel for every TPT resident on the TSS. A single TPT cannot be
isolated and set individually.
On the TSS four segment display, use the up and down arrows to select the desired channel
for the TPTs.
Press and release ENTER key once to initiate the change setting. All TPT units will now be
set to the same channel.