![Telephonics Trulink User Manual Download Page 19](http://html1.mh-extra.com/html/telephonics/trulink/trulink_user-manual_1082113019.webp)
T
E L E P H O N I C S
C
O R P O R A T I O N
TM115007 REV A (04/07)
2-7
USE OR DISCLOSURE OF DATA CONTAINED ON THIS PAGE IS SUBJECT TO THE
RESTRICTION ON THE TITLE PAGE OF THIS DOCUMENT
.
C
O M M U N I C A T I O N
S
Y S T E M S
D
I V I S I O N
Table 2.6.1-1
LED Indications
STATUS
COLOR
ON TIME (MS)
OFF TIME (MS)
BATT OK, Slave logged on to network
GREEN 100
1900
LOW BATT, Slave logged on to network
RED 100
1900
CHARGE BATT, Slave logged on to network
RED-GREEN
50 + 50
1900
NORMAL, Master logged on to network
GREEN 100/100
150/1650
LOW BATT, Master logged on to network
RED 100/100 150/1650
CHARGE BATT, logged on to network
RED-GREEN
50 + 50/50 + 50
150/1650
CONNECTED BATT OK, Slave connected to
platform
GREEN 200/100
800/900
CONNECTED LOW BATT, Slave connected and
low battery
RED 200/100 800/900
CONNECTED CHARGE, Slave connected and
charging battery
RED-GREEN
100 + 100/50 + 50
800/900
CONNECTED BATT OK, Master connected to
platform
GREEN 200/100/100
800/150/650
CONNECTED LOW BATT, Master connected
and low battery
RED 200/100/100
800/150/650
CONNECTED CHARGE, Master connected and
charging battery
RED-GREEN
100 + 100/50 +
50/50 + 50
800/150/650
OUT OF RANGE, normal battery
GREEN 500
500
OUT OF RANGE, low battery
RED 500
500
OUT OF RANGE, charging battery
RED-GREEN
250 + 250
500
POWER UP BOOT
RED 1000
0
POWER UP
RED 1000
0
MALFUNCTION (BIT failure, fatal error)
RED 1000
0
SW DOWNLOAD READY
GREEN 200
200
SW DOWNLOAD IN PROGRESS
GREEN 10
100