MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 5
4. MODEM SPECIFICATIONS
Modulation:
Bell202T
Modulation
Type:
FSK
Synch/Async:
Synchronous or Asynchronous
Data
Rate:
0 – 1200bps
Transmit
Frequency:
Mark: 1200Hz
Space: 2200Hz
Error
Correction:
None
Data
Compression:
None
Data Modulation Connectivity:
Using 16ms Polling Test
99.999% or better at -37dBm
99.5% or better at -40dBm
95% or better at -43dBm
Serial Formats and Flow Control:
Synchronous or Asynchronous and RTS/CTS flow control
Analog
Interface
Tx Output Level:
-0 dBm or -10 dBm *
Rx Sensitivity:
-43dBm or -33dBm *
-43dBm for constant carrier
-40dBm for polling carrier
Line Termination:
Dip Switch Selectable *
Line Impedance:
600 ohms balanced
2 or 4 Wire Configuration:
Dip Switch Selectable *
Summary of Contents for 202T-S
Page 12: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 10 7 POWER CONNECTIONS...
Page 17: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 15 11 LED INDICATOR...
Page 23: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 21...
Page 24: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 22...
Page 25: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 23...
Page 26: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 24 NOTES...