background image

MIU202T-S Installation, Operation & Diagnostics    Edition:  March 16, 1999   Page 6

 

 

 

Other Features 

 
 Receiver 

Equalization: 

Compromise 

Equalization 

 

Self Test Diagnostics: 

None 

 

Local Analog Loopback: 

See Section 13 

 

Local Digital Loopback: 

See Section 13 

 

Remote Analog Loopback 

See Section 13 

 

Remote Digital Loopback 

See Section 13 

 Anti-Streaming: 

OFF or 45 Seconds (+ 5 sec) * 

 

RTS/CTS delay: 

1ms, 12ms, 35ms or 50ms (+5%) * 

Note: Soft Carrier will effect 

RTS/CTS delay time (see Dip 

Switch Settings ~ Section 8) 

 

 Constant 

Carrier 

Switch 

Selectable  ON or OFF 

 

Soft Carrier Turn Off 

20ms of  900Hz after RTS is turned 

Off  

 

Carrier Turn ON/OFF 

8ms +0.5ms 

 

 

* Dip Switch Selectable ~ See Section 9 

Summary of Contents for 202T-S

Page 1: ...Document No 49 0002 017 Rev A Installation Operation Diagnostics for the MIU202T S Industrial Grade Bell 202T S Standalone Modem...

Page 2: ...Document No 49 0002 017 Rev A Telenetics Corporation 26772 Vista Terrace Drive Lake Forest California 92630 949 455 4000 Fax 949 455 4010...

Page 3: ...VERVIEW 3 3 GENERAL PRODUCT SPECIFICATIONS 4 4 MODEM SPECIFICATIONS 5 5 ANALOG LINE SPECIFICATIONS 7 6 ANALOG MICROWAVE INTERFACE 8 7 POWER CONNECTIONS 10 8 SERIAL DATA PORT PIN OUT 11 9 DIP SWITCH FU...

Page 4: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 2 Meets FCC Rules Part J Subpart 15 Class A for radiated emissions...

Page 5: ...Though functionally similar to commercial modems the MIU202T includes special features that make it particularly well suited for utility and industrial applications Environment The MIU202T has been d...

Page 6: ...Supply Standard Model 40 to 270VDC 40 to 270VAC 50 60Hz LV Model Suffix LV 9 to 36VDC Current Requirements 12VDC 24VDC 125VDC 120VAC 220VAC 65mA 27mA 7 5mA 6 5mA 5 5mA Surge Protection Power Supply 8k...

Page 7: ...ession None Data Modulation Connectivity Using 16ms Polling Test 99 999 or better at 37dBm 99 5 or better at 40dBm 95 or better at 43dBm Serial Formats and Flow Control Synchronous or Asynchronous and...

Page 8: ...See Section 13 Remote Analog Loopback See Section 13 Remote Digital Loopback See Section 13 Anti Streaming OFF or 45 Seconds 5 sec RTS CTS delay 1ms 12ms 35ms or 50ms 5 Note Soft Carrier will effect R...

Page 9: ...will also interface to Power Line Carrier or Microwave radio voice channel networks The MIU202T has an RJ 11terminated connector The following lists the MIU202T analog interfaces Analog Line Type Cond...

Page 10: ...month Level Stability w o regulation 0 5 dB 6 months Harmonic Distortion 1 max 0 3 typical 1Khz 0 dBmO test tone Absolute Delay Option 001 1500 sec maximum Option 002 1900 sec maximum Group Delay opt...

Page 11: ...hannel 28dBrnc0 maximum 24 455B weighted noise at 0 dBmO dBrnc0 typical Intra channel 28 dBrnc0 maximum 18 dBrnc0 typical 1KHz test tone at 0 dBmO Out of Band Signalling Frequency 3825 Hz Level 20 dBm...

Page 12: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 10 7 POWER CONNECTIONS...

Page 13: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 11 8 SERIAL DATA PORT PIN OUTS For Synchronous Mode 6 TxDClk was DSR 15 TxDClk 9 RxDClk was RI 17 RxDClkl...

Page 14: ...gnal Level 0 dBm 10 dBm Switch 2 Anti Streaming 45 secs OFF Switch 3 Received Analog RxA Signal Level 33 dBm 43 dBm Switch 4 RTS CTS Delay See Table 2 Switch 5 RTS CTS Delay See Table 2 Switch 6 Switc...

Page 15: ...0 ms NO YES YES NO ON ON ON 50 ms YES NO YES NO ON ON OFF 50 ms NO YES YES YES OFF ON OFF 35 ms NO YES YES NO OFF ON ON 35 ms YES NO YES NO OFF ON ON 35 ms YES NO YES NO OFF ON OFF 35 ms NO YES YES YE...

Page 16: ...7 8 9 4 Wire Point to Point ON ON ON ON 4 Wire Multi Point Master ON ON ON ON 4 Wire Multi Point Slave Rx Term OFF ON ON ON ON ON 4 Wire Multi Point Slave Rx Term ON ON ON ON ON ON ON 2 Wire Point to...

Page 17: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 15 11 LED INDICATOR...

Page 18: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 16 12 OUTLINE DRAWING MOUNTING...

Page 19: ...tor on the modem under test Set Dip Switches as follows Switch 7 OFF 4 Wire Switch 9 ON Soft Carrier Turn Off Enabled Switch 1 ON Transmit TxA Signal Level 0dBm Switch 3 ON Receive RxA Signal Level 33...

Page 20: ...elay times and with soft carrier ON and OFF b LOCAL DIGITAL LOOPBACK 4 Wire Network Figure 4 On the modem under test connect TxD to RxD Switch 1 ON TxA 0dBm Switch 3 ON RxA 33dBm Switch 4 OFF RTS CTS...

Page 21: ...TxA 0dBm Switch 3 ON RxA 33dBm Switch 4 OFF RTS CTS 35ms Switch 5 ON RTS CTS 35ms Switch 6 ON Constant Carrier mode Switch 7 OFF 4 Wire Switch 8 ON Line Termination 600 ohms Switch 9 ON Soft Carrier T...

Page 22: ...al modem configuration for 4 wire Multi Point system Switch 1 ON TxA 0dBm Switch 3 ON RxA 33dBm Switch 4 OFF RTS CTS 1ms Switch 5 OFF RTS CTS 1ms Switch 6 ON Constant Carrier mode Switch 7 OFF 4 Wire...

Page 23: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 21...

Page 24: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 22...

Page 25: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 23...

Page 26: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 24 NOTES...