MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 20
(d)
LINE DIAGNOSTICS
(i) Typical modem configuration for
4-wire Point-to-Point
system…
Switch 1 = ON (TxA = 0dBm)
Switch 3 = ON (RxA = -33dBm)
Switch 4 = OFF (RTS/CTS = 1ms)
Switch 5 = OFF (RTS/CTS = 1ms)
Switch 6 = ON (Constant Carrier mode).
Switch 7 = OFF (4-Wire)
Switch 8 = ON (Line Termination = 600 ohms)
Switch 9 = OFF (Soft Carrier = OFF)
(ii) Typical modem configuration for
4-wire Multi-Point
system…
Switch 1 = ON (TxA = 0dBm)
Switch 3 = ON (RxA = -33dBm)
Switch 4 = OFF (RTS/CTS = 1ms)
Switch 5 = OFF (RTS/CTS = 1ms)
Switch 6 = ON (Constant Carrier mode).
Switch 7 = OFF (4-Wire)
Switch 8 = ON (Line Termination = 600 ohms)
Switch 9 = OFF (Soft Carrier = OFF)
Adjustments…
In a network with high line loss (greater than 16dB) change Switch 3
(RxA) to OFF (-43dBm).
If there are conditions that can cause cross-talk (TxA leaking into RxA
path) set Switch 1 (TxA) to OFF (-10dBm).
Note that noise level should be –50dBm or lower for most FSK
operation (signal-to-noise ratio of 15dB or higher)
Summary of Contents for 202T-S
Page 12: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 10 7 POWER CONNECTIONS...
Page 17: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 15 11 LED INDICATOR...
Page 23: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 21...
Page 24: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 22...
Page 25: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 23...
Page 26: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 24 NOTES...