MIU202T-S Installation, Operation & Diagnostics Edition: March 16, 1999 Page 17
13. DIAGNOSTICS
The following pages provide hardware techniques for diagnosing
communication problems and thereby isolating the problem at the local
modem, the remote modem or the interconnecting line.
(a) LOCAL ANALOG LOOPBACK (Figure 2)
Requires a loop back cable with a built-in circuit for line loss to
simulate a typical leased line condition (See Figure 3).
Connect the loop back cable to the RJ11 connector on the modem
under test.
Set Dip Switches as follows…
Switch 7 = OFF
4-Wire
Switch 9 = ON
Soft Carrier Turn Off Enabled
Switch 1 = ON
Transmit (TxA) Signal Level = 0dBm
Switch 3 = ON
Receive (RxA) Signal Level = –33dBm
Switch 6 = OFF
Switched Carrier
Switch 4&5 = ON
RTS/CTS Delay = 50ms
Test 1: RTS/CTS Analog Control
Set RTS “ON” and check that CD (Carrier Detect) turns
“ON”.
Turn RTS “OFF” and ensure that CD turns “OFF”
With RTS “ON”, run a test message at TxD and verify that
the same message is received at RxD with no data errors.
Test 2: Transmit Signal Power & Receive Levels
Set Dip Switch 1 OFF (TxA = -10dBm)
CD will be OFF.
Change Dip Switch 1 to ON (TxA = 0dBm)
CD should now be ON.
Test 3: Received Signal Level
Summary of Contents for 202T-S
Page 12: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 10 7 POWER CONNECTIONS...
Page 17: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 15 11 LED INDICATOR...
Page 23: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 21...
Page 24: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 22...
Page 25: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 23...
Page 26: ...MIU202T S Installation Operation Diagnostics Edition March 16 1999 Page 24 NOTES...