86
2.4 To Set Sweep Function
In sweep mode, the generator changes the output frequency between the start
frequency and the stop frequency in the sweep time specified by the user. The
waveforms that support sweep include sine, square, ramp and arbitrary. Press
Sweep key to enter the following menu. Set the waveform parameters by
using the operation menu.
Figure 2-56 Setting Interface of Sweep (Page 1/2)
Table 2-20 Menu Explanations of Sweep (Page 1/2)
Funtion Menu
Settings
Explanantion
Sweep time
The time span of the sweep in which the
frequency changes between the start
frequency to stop frequency
Start Freq
Mid Freq
The start frequency of the sweep
The center frequency of the sweep
Stop Freq
Freq Span
The stop frequency of the sweep
The frequency span of the sweep
Source
Internal
Choose internal source as a trigger
External
Choose external source as a trigger
Use the [Aux In/Out] connector at the rear
panel
Manual
Trigger a sweep by manual
Trig Out
Off
Disable trigger output
On
Enable trigger output
Page 1/2
Enter the next page