Teledyne
LeCroy
Recording
Options
Setup
38
Kibra
DDR
Protocol
Analyzer
User
Manual
2.6.1
Recording Options - General Tab
The
following
settings
can
be
set
from
the
General
tab.
The
options
on
the
General
tab
are
explained
below.
Product
Select
a
product
for
the
recording
options
from
either
Kibra
380
Protocol
Analyzer
or
Kibra
480
Protocol
Analyzer.
Recording Type: Trigger Mode
The
Trigger
Recording
Options
dialog
allows
you
to
specify
when
the
analyzer
completes
a
data
capture.
Three
trigger
modes
are
available:
The
default
Snapshot,
Manual
Trigger,
and
Event
Trigger.
When
data
capture
starts
with
Snapshot
selected,
the
analyzer
triggers
on
the
first
data
pattern
on
the
bus.
Starting
a
data
capture
with
Event
selected
triggers
when
specific
event(s)
are
detected
in
the
captured
data
stream.
The
following
three
ways
can
trigger
the
analyzer
with
Event
selected:
Trigger
on
Specific
DDR3
or
DDR4
Commands
Trigger
on
DDR3
or
DDR4
Protocol
or
Timing
Violations
External
Trigger
‐
in
(from
other
test
equipment)
Figure 2.7: Trigger Setup
Snapshot Mode
To
capture
immediately
on
any
trace,
check
the
Snapshot
button.
Manual Trigger Mode
In
the
Manual
Trigger
mode,
the
analyzer
captures
bus
traffic
continually
from
when
you
use
the
Start
button
until
you
click
the
Manual
Trigger
button
(on
the
analyzer
toolbar),
which
triggers
the
analyzer.
To
perform
a
manual
trigger,
click
the
Manual
Trigger
button.
This
selection
also
enables
the
External
SMA
Trigger
function.
Summary of Contents for Kibra DDR
Page 10: ...Teledyne LeCroy Contents 8 Kibra DDR Protocol Analyzer User Manual ...
Page 101: ...Kibra DDR Protocol Analyzer User Manual 99 Help Teledyne LeCroy Figure 2 73 Shortcut List ...
Page 168: ...Teledyne LeCroy 166 Kibra DDR Protocol Analyzer User Manual ...
Page 170: ...Teledyne LeCroy 168 Kibra DDR Protocol Analyzer User Manual ...