M-412-073 Appendix B: Technical Specifications
TELEDYNE TAPTONE
44
B.2 Fill_xr Sensor Specifications
X-Ray Sensor Specifications
ENCLOSURE
Dimensions:
31.1 cm high x 17.15 cm wide x 64.77 cm deep (12.25 in. x 6.75 in. x 25.5 in.)
Construction:
Single piece box w/ screw mount access panel
Material:
Brushed stainless steel
Environmental Rating:
NEMA 4X, IP65
Wash Down Rating:
High-pressure water
Mounting:
Pedestal stand to floor secured to conveyor
STAND
Type:
Adjustable height
Travel Range:
Crank handle fine adjust 304.8 mm (12 in.)
Overall floor to X-ray beam range (does not include fine adjust range) standard
post 50.8-228.6 cm (20-90 in.)
– Longer Lengths are available upon request
Construction:
Brushed stainless steel
X-ray Source:
X-ray tube, 35-60 kV, 10-30uA, 24 VDC @ 2 A, +/- 15 VDC @
300 mA
X-ray Lamp:
Red lens (Green for CE), 24 VDC, 6.5 watt LED (monitored for
continuity)
X-ray Detector:
Photo Multiplier Tube (PMT), 25.4 mm (1 in.) square window
Trigger Sensor:
Thru-beam pair, adjustable gain, 10-30 VDC, sourcing pnp output