![Teledyne TapTone T4000 APX Installation Manual Download Page 24](http://html1.mh-extra.com/html/teledyne-taptone/t4000-apx/t4000-apx_installation-manual_1081094024.webp)
M-412-073 Chapter 3: Installation Instructions
TELEDYNE TAPTONE
17
3.2 T4000 AC, P Stand Installation
3.2.1 RTV Crank Stand Installation
6 Feet (1.82 meters)
9” (228mm)
9-1/2” (241mm)
Lag Bolts
Figure 3-1 Transducer Stand Assembly (RTV)
1. Select a location where the transducer stand will be mounted. Make sure the location is
smooth and straight. The rails must be straight and guide the containers smoothly
through the inspection head. The location should allow the rejector to be mounted on the
conveyor with an adequate size collection bin.
2. The transducer crank stand has 9.5 inches (241 mm) of travel. The stand is shipped with
the following inspection range:
Max. height: MXS = 66 inches (1676 mm)
Min. height: MNS = 56.5 inches (1435 mm)
3. Measure the conveyor tabletop height and the tallest and shortest containers. Enter the
values below.
CH - Conveyor Height =
TC - Tallest Container =
SC - Shortest Container =