background image

PCI Express 3.0 - CrossSync PHY and Compliance Test Capable

Recommended Oscilloscope Probes

Oscilloscope Software Options

The Oscilloscope Software options allow you to enable CrossSync PHY functionality on installed CrossSync software.

Recommended Oscilloscopes

CrossSync PHY is compatible with all LabMaster 10 Zi and WaveMaster 8 Zi series oscilloscopes. Below are some 
recommendations for example test configurations.

PCI Express 4.0 - CrossSync PHY and Compliance Test Capable

Product Description

Product Code

13 GHz (or higher), 40 GS/s, 4ch, 64 Mpts/Ch Serial Data Analyzer
with 6.5 Gb/s Serial Trigger, 8b/10b and 64b/66b decode.

SDA 813Zi-B

Product Description

Product Code

High-speed Data Signals

8 GHz differential probe with ProLink interface

DH08-PL

13 GHz differential probe with ProLink interface 

DH13-PL

16 GHz differential probe with ProLink interface 

DH16-PL

20 GHz differential probe with ProLink interface 

DH20-PL

25 GHz differential probe with 2.92 mm interface

DH25-2.92MM

30 GHz differential probe with 2.92 mm interface

DH30-2.92MM

Rail Voltage/current Points

Power/Voltage Rail Probe. 4 GHz bandwidth, 1.2x attenuation, ±30V offset, ±800mV

RP4030

Product Description

Product Code

CrossSync PHY option for LabMaster 10 Zi - sync oscilloscope with PCIe Protocol Analyzer hardware 

 

LM10Zi-CrossSyncPHY-PCIe

CrossSync PHY option for WaveMaster 8 Zi - sync oscilloscope with PCIe Protocol Analyzer hardware

 

WM8Zi-CrossSyncPHY-PCIe

Product Description

Product Code

25 GHz (or higher), 80 GS/s, 4 Ch, 32 Mpts/Ch LabMaster 10 Zi Acquisition Module

LabMaster 10-25Zi-A

LabMaster Master Control Module 

LabMaster MCM-Zi-A

Summary of Contents for PCI Express Gen4 M.2

Page 1: ...other non storage devices Socket 3 keyed as M is strictly for high performance storage offering x4 lanes of bandwidth in this form factor In some cases a B M keyed SSD will also be available and it is...

Page 2: ...tach and secure the Teledyne LeCroy M 2 interposer cable on the host system which usually supports different M 2 card form factors Follow below instructions to install the extension brackets that will...

Page 3: ...ble soldered to the top of the PCB was removed in the drawing below for clarity 5 Insert the Extension bracket with the clip into the PCB with cables attached Ensure that the alignment pins on the bra...

Page 4: ...nt bracket follow below procedure The Teledyne LeCroy M 2 Interposer Extension Bracket Kit contains the items listed below The items are shown in the figure below Type 22110 Extension bracket Type 228...

Page 5: ...er 5 The view from the top side of the PCB is shown below The text Type 2280 is clearly visible Attaching the Cables to the Interposer 1 Once the cable assembly has been completed Method One or Method...

Page 6: ...22110 Move the M 2 standoff based on the DUT Type The standoff will be attached to 2280 location by default The DUT is secured by a thumbscrew on the top side and a standoff with a locknut on the bot...

Page 7: ...it for it to be recognized by the application Note If prompted to update the firmware please do that before proceeding 9 Start recording with the analyzer 10 Power on the host machine 11 Launch the Te...

Page 8: ...to the next active width as indicated by the LEDs next to the switch on the interposer DUT Power LED Status on Interposer SW4 This switch connects the DUT power indication LEDs to the bus power In so...

Page 9: ...F Protocol Analyzer US Clock Cable A Side Band Test Point Header J6207 Connector Pin Number Signal Name Connector Pin Number Signal Name 1 No Connection 17 VIO_CFG_HDR 2 No Connection 18 No Connection...

Page 10: ...sis software and MAUI oscilloscope software optional Signal Name PE210UIA X PE210UIA X 1PHY PE210UIA X 2PHY PE210UIA X 4PHY Pin Headers CLK_32KHZ SUSCLK X X X X DAS DSS LED_1 X X X X ALERT IN X X X X...

Page 11: ...erential probe with ProLink interface DH08 PL 13 GHz differential probe with ProLink interface DH13 PL 16 GHz differential probe with ProLink interface DH16 PL 20 GHz differential probe with ProLink i...

Page 12: ...d Top View 2 Locate the PCIe Express pairs probe points as located on the left and right sides of the interposer Left Side View Right Side View Buffered Refclk Copy UMC Pin Header for Sideband Signals...

Page 13: ...nnect the oscilloscope probes to the PCI express signals as shown in the figure below Connect each Oscilloscope Probe to the Required PCIe Bus Signal Interposer Ready for a Scope Analysis of a PCIe x2...

Page 14: ...emarks of Teledyne LeCroy All other trademarks are property of their respective companies Changes Product specifications are subject to change without notice Teledyne LeCroy reserves the right to revi...