Installation instructions
│
R2
│
Annex A: Implementation Specifications – Lynx (in
English)
A .2 .1 1 DI S C RET E I N PUT S O N S T A T I O N A RY UN I T – 0 X0 2 0 1
Bit
Contents
0 (Input 1)
0 = Not Active
1 = Active
1 (Input 2)
0 = Not Active
1 = Active
15–2
Reserved
A .2 .1 2 S A MPL ED I N PUT PO W ER O N S T A T I O N A RY UN I T – 0 X0 60 0
Bit
Contents
15–0
Sampled voltage in millivolts
A .2 .1 3 L ED S T A T E REG I S T ERS – 0 X0 A 0 0 – 0 X0 A 0 3
Only the lower 8 bits are used to define the state.
Bit
Contents
7-0
State (Default 0x00)
15-8
Reserved
Supported states:
State
Description
0x00
LED OFF (Default)
0x01 – 0x10
Reserved
0x11
0.125 second single blink
0x12
0.25 second single blink
0x13
0.5 second single blink
0x14
1 second single blink
0x15
2 second single blink
0x16
4 second single blink
0x17
8 second single blink
0x18 – 0xFE
Reserved
0xFF
LED ON
A .2 .1 4 DI S C RET E O UT PUT S O N S T A T I O N A RY UN I T – 0 X1 0 0 0
This register controls the open collector outputs on the stationary unit.
IM-LX-RX101-EN-v01
33