Installation instructions
│
R2
│
Annex A: Implementation Specifications – Lynx (in
English)
Value
Baudrate
3
57600 baud
A .2 .9 RS 48 5 S ERI A L PO RT MO DE – 0 X0 0 0 A
Value
Baudrate
0 (default)
8 bits, Even parity, 1 stop bit
1
8 bits, Odd parity, 1 stop bit
2
8 bits, No parity, 2 stop bits
3
8 bits, No parity, 1 stop bit
A .2 .1 0 T RA N S MI T T ER B UT T O N S T A T E – 0 X0 2 0 0
The button state register is reset to all zeroes if the stationary unit if the
stationary unit has not received radio packet with button activity for 300ms.
Bit
Contents
0 (Button 1)
0 = Non active
1 = Active
1 (Button 2)
0 = Non active
1 = Active
2 (Button 3)
0 = Non active
1 = Active
3 (Button 4)
0 = Non active
1 = Active
4 (Button 5)
0 = Non active
1 = Active
5 (Button 6)
0 = Non active
1 = Active
6 (Button 7)
0 = Non active
1 = Active
7 (Button 8)
0 = Non active
1 = Active
15-8
Reserved
32