37
GB
- The gate closes.
- Upon completion of programming the LED L1 goes out
The incorporated receiver self-memorises the codes of the TANGO range.
To memorise the transmitters, proceed as follows:
- Power the control unit
- Ensure that the functions dip switch No. 10 is in the ON position.
- Briefly press the Stop/Prog. button (Part 2 of fig. 1) on the control unit; the LED L1 starts to blink.
- Transmit with the remote control to be programmed.
- If the LED L1 blinks for a longer time, this means that storage has been successful.
- If the code is already stored, the LED L1 gives a series of short blinks.
- Code storage may be reset by keeping the Stop/Prog. Button pressed for approx. 10 seconds until L1
comes on.
- Should this incorporated receiver not be used, IT MUST be cut out by putting dip switch 10 to the OFF
position.
PROGRAMMING THE RADIO
If it is necessary to connect 2 motors (e.g. in installations for overhead doors), connect the 2 motors and the
2 capacitors in parallel directly onto the T100 terminal board.
PARALLEL CONNECTION OF 2 MOTORS
1) ENCODER FUNCTION (only on some versions)
The new Telcoma sliding gate motors mod. SML are fitted as standard supply with an encoder output that
is compatible with the latest control units T100, T100SW.
The benefits of using these new products:
- detection of obstacles throughout the whole of gate movement (EN 12445)
- precision of movement (the encoder detects real gate movement)
NEW FUNCTIONS T100 - T100SW
If any recoils of the gate are noted when passing from normal to a lower speed on an installation where the
slowdown function is used, the mode of passage may be changed as follows:
A - cut off the power supply
B - press the pushbuttons PP and STOP on the control unit simultaneously (parts 1 and 2 of fig. 1)
C - reconnect to the power supply, keeping the buttons pressed.
D - the LED L1 (part 6 of fig. 1) gives a short signal that the passage is successful.
To return to the initial configuration, simply repeat the above procedure.
In the
T100F
and
T100F SW
versions for overhead door automation, if the slowdown function is inserted
it only operates during closure. Furthermore, when the closing limit switch activates or the closure working
time elapses, the control unit continues to provide the motor with power for approx. one more second.
SLOWING DOWN