DESCRIPTION OF PARTS in Fig. 1
31
GB
1) Step-by-step
(P/P)
pushbutton
2) Programming and Stop* pushbutton
3) Trimmer for motor power
4) Jumper Jp1 (soft-start and motor power adjust-
ment bypass)
5) Terminal board for auxiliaries power supply and
gate open warning light connection
6) Programming
of
LED
(L1)
7) Jumper
test
8) Fuse 24V 0.3A
9) Line fuse 6,3A
10) Terminal board for power supply line connec-
tion
11) Terminal board for courtesy and flashing light
connection
* This STOP button
is not a safety button
but serves solely to facilitate tests during installation.
12) Terminal board for motor and capacitor connec-
tion
13) Optional Anti-crush card (MAS 100)
14) Control unit reset. Short-circuiting the 2 pins
for a moment is equivalent to cutting off and
reconnecting to the power supply.
15) Incorporated radio card compatible w. Tango
range
16) Functions dip switches
17) Connector for receiver connection
18) Indicator lights (LED) related to the terminal
board inputs. LED on = input closed
19) Terminal board for receiver antenna and con-
trols connection
Description of T100 control unit models:
T100
control unit for sliding or swing gate automation with 1 motor, incorporated TANGO range recei-
ver
T100F
control unit for overhead door automation with 1 or 2 motors, incorporated TANGO range recei-
ver
T100 SW
control unit for sliding or swing gate automation with 1 motor, incorporated TANGO SW range
receiver
T100F SW
control unit for overhead door automation with 1 or 2 motors, incorporated TANGO SW range
receiver
The control units are equipped with:
- electronic torque regulation
- motor slowdown
- motor brake
- photo test
- Triac test (motor control self-diagnosis)
- anti-crushing system (optional MAS 100)
The T100 control unit is unsuitable for controlling motors with condenser and limit switch already wired
directly inside the actual motor (e.g. motors for roller shutters).
MODELS
INSTRUCTIONS FOR INSTALLING THE ELECTRONIC CONTROL UNIT T 100
Please read these instructions carefully before installing the control unit.
Improper use or a connection error could jeopardise correct operation of the product and endanger