background image

SS02 - USER MANUAL 

Space Scan Series 

Photoelectric measurement light curtains 

 

 

Website:  www.telcosensors.com

 

 

Warning

 

V 1.6 Part Number:

 

L40-0666220746 

E-Mail:     [email protected] 

 

This device is not to be used for Personnel Protection in Machine 

Guarding Safety applications. This device does not include the self-

checking redundant circuitry necessary to allow its use in personnel 

machine guarding stand-alone safety applications. 

April 2019 edition 

 

Made in Denmark

 

Telco A/S reserves the right to make changes without prior notice 

Page 3 of 7

 

 

 

tel 

EN 

 

File menu 

 

RS485 Serial Port and Modbus Setup:

 

See SSR02 and PC connection. 

 

Search for Telco light curtains on a Modbus.

 

Used for finding and identifying the Modbus address(es) of one or more light curtains on the 

Modbus. For more info see below.

 

 

Connect

 

See SSR02 and PC connection.

 

 

Load configuration 

Used to load a file that will configure all functions of the light curtain in one go. The information 

is stored in a previously saved configuration file in ASCII format.

 

 

Save configuration

 

Saves information about the current configuration of the light curtain.

 

 

Colour Preference 

It is possible to set up to 7 different colours for the beams on the screen.

 

 

Exit

 

Exit and close the program. 
 

Language 

Language selection. 

 

 

 

 

 

 

 

 

 

 

File -> Search for Telco Light curtain on a Modbus 

Use this function to find the 

Modbus Address(es)

 of Telco Light curtains on a Modbus, if the address(es) are unknown. 

 

 

 

 
 
 
 
 
 
 
 
 
 

Functions menu 

 

 

Overview: 

 

For configuration of outputs and measurement functions and for reading output states. 
 

System Information:

 

For basic system information and configuration of Modbus address. 

 

Status Messages:

 

Status messages are logged and displayed by choosing this menu item. 

Each functions associated with each of these menu items will be described in detail the 

following. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Functions -> Overview -> General Setup tab 

 

General Setup

:  

Right side shows the light curtain and the beam pattern. Unbroken or made beams are indicated by green and broken beams by red. The light curtain is in the setup oriented with the cable entry in the 

bottom.

 

 

Summary of Contents for Space Scan SS02 Series

Page 1: ...g pages Before using it check the power supply complies with electrical data 1 Mount the transmitter SST and receiver SSR facing each other and correctly aligned 2 Wire the sensor according to the wir...

Page 2: ...o make changes without prior notice Page 2 of 7 tel EN SSR02 and PC connection To setup or adjust a SS02 it is required to use the Telco Space Scan Terminal software together with an RS485 data link 1...

Page 3: ...go The information is stored in a previously saved configuration file in ASCII format Save configuration Saves information about the current configuration of the light curtain Colour Preference It is...

Page 4: ...re the status of the beams are ignored Blanking can either be setup by writing directly which beams to be blanked in the text box Writing 12 16 20 means that all beams starting from beam no 12 and end...

Page 5: ...de Position of the first beam made LBB Last Beam Blocked Position of the last beam blocked LBM Last Beam Made Position of the last beam made MBB Middle Beam Blocked Position of the FBB LBB 2 rounded t...

Page 6: ...aluation of a Boolean expression that here is set up using the two pull down boxes and text input box The first box contains the same list of functions as available under Analogue Output Function plus...

Page 7: ...oes not include the self checking redundant circuitry necessary to allow its use in personnel machine guarding stand alone safety applications April 2019 edition Made in Denmark Telco A S reserves the...