SS02 - USER MANUAL
Space Scan Series
Photoelectric measurement light curtains
Website: www.telcosensors.com
Warning
V 1.6 Part Number:
L40-0666220746
E-Mail: [email protected]
This device is not to be used for Personnel Protection in Machine
Guarding Safety applications. This device does not include the self-
checking redundant circuitry necessary to allow its use in personnel
machine guarding stand-alone safety applications.
April 2019 edition
Made in Denmark
Telco A/S reserves the right to make changes without prior notice
Page 2 of 7
tel
!
EN
SSR02 and PC connection
To setup or adjust a SS02 it is required to use the Telco Space Scan Terminal software together with an RS485 data link.
1.
Start by selecting the
RS485 Serial Port and Modbus Set Up
and select the correct port to communicate with the SS02. If the port number is not known it is possible to press the
Get
Com Port Information
. This will list all COM Ports used by the PC. (Full Com port details in Win7, WinXP only basic details are shown ). The
RS485 BUS ADDRESS
is default 127, but
address can be changed in the menu Function -> System Information.
2.
Next press
Connect
and wait a few seconds before the connection is active.