SS02 - USER MANUAL 

Space Scan Series 

Photoelectric measurement light curtains 

 

 

Website:  www.telcosensors.com

 

 

Warning

 

V 1.6 Part Number:

 

L40-0666220746 

E-Mail:     [email protected] 

 

This device is not to be used for Personnel Protection in Machine 

Guarding Safety applications. This device does not include the self-

checking redundant circuitry necessary to allow its use in personnel 

machine guarding stand-alone safety applications. 

April 2019 edition 

 

Made in Denmark

 

Telco A/S reserves the right to make changes without prior notice 

Page 6 of 7

 

 

 

tel 

EN 

 

Functions -> Overview –> Digital Output tabs 

The 

Digital Output 1 

tab, selected under 

Function->Overview,

 it is possible to define the operation of 

Digital Output 1

.  

If the light curtain is equipped with multiple digital outputs, the other outputs can be configured by using the other identical digital output tabs.  

The digital output tab contains 3 marked areas:  

Digital Output

Digital Output Function

 and 

Set Digital Output

 

Digital Output

: To 

Enable Output

 and 

Disable Output

.  

 

Digital Output Function: 

A digital output can read out only two values which are associated with the Boolean values true and false; the output is either high = true or low= false.   

The output value is the result of the evaluation of a Boolean expression, that here is set up using the two pull down-boxes and text input box.  

 

The first box contains the same list of functions as available under Analogue Output Function, plus the ABBA function.  

 

The second box contains a list of comparison operators.  

 

The third box is used to type in a number. If the expression is true, the out will be high, and if the expression is false, the output will be low. 

The selection “Any Beam Blocked in Area” has two values minimum and maximum. The output is high if one or more beams are broken with beam numbers that are larger than or equal to  

Minimum and smaller than or equal to Maximum. 

With the selection “Signal Alarm” the output is set high if the signal is not OK. 

 

Set Digital Output  

Marking the checkbox 

Force Set Enable

 disables the 

Digital Output Function

 and enables the user to set the digital output high by selecting 

Output Forced High

 or low by selecting 

Output Forced 

Low

.  The function is primarily intended for test purposes. 

 

Output delay:

 On-delay specify the time between the expression becomes true and the output is switched accordingly. Off-delay specify the time between the expression becomes false and the output 

is switched. On-delay and off-delay is selectable between 0 and 10 s.

 

 

 

 

 

 

Functions -> System information 

System information contains the information displayed in the figure below. The MODBUS address can be modified using the Change MODBUS Address button.

 

 

 

 

Summary of Contents for Space Scan SS02 Series

Page 1: ...g pages Before using it check the power supply complies with electrical data 1 Mount the transmitter SST and receiver SSR facing each other and correctly aligned 2 Wire the sensor according to the wir...

Page 2: ...o make changes without prior notice Page 2 of 7 tel EN SSR02 and PC connection To setup or adjust a SS02 it is required to use the Telco Space Scan Terminal software together with an RS485 data link 1...

Page 3: ...go The information is stored in a previously saved configuration file in ASCII format Save configuration Saves information about the current configuration of the light curtain Colour Preference It is...

Page 4: ...re the status of the beams are ignored Blanking can either be setup by writing directly which beams to be blanked in the text box Writing 12 16 20 means that all beams starting from beam no 12 and end...

Page 5: ...de Position of the first beam made LBB Last Beam Blocked Position of the last beam blocked LBM Last Beam Made Position of the last beam made MBB Middle Beam Blocked Position of the FBB LBB 2 rounded t...

Page 6: ...aluation of a Boolean expression that here is set up using the two pull down boxes and text input box The first box contains the same list of functions as available under Analogue Output Function plus...

Page 7: ...oes not include the self checking redundant circuitry necessary to allow its use in personnel machine guarding stand alone safety applications April 2019 edition Made in Denmark Telco A S reserves the...

Reviews: