Command
Description
Command Example and
Feedback
/+PU[
x
]:
zzzz
Set the ASCII “Power On” command "XXXX" to
be sent to remote display device when powering
on the switcher
x
= Baud rate (1 ~ 5)
1 - 115200
2 - 57600
3 - 38400
4 - 19200
5 - 9600
zzzz
= ASCII data to be sent (Up to 48
characters)
Notes
:
1.
When reading “
\
x”, the two characters after
“
\
x” will be converted to HEX automatically
2.
When typing “
\\
”, only one “
\
” will be sent
3.
When reading “
\
r” immediately after “
\
x”, “
\
r”
will be converted to “0x0D” in HEX
4.
When reading “
\
n” immediately after “
\
x”, “
\
n”
will be converted to “0x0A” in HEX
/+PU[5]:PowerOn\x31
Baudrate: 9600
Power on to send:PowerOn1
/-PU[
x
]:
zz zz
Set the HEX “Power On” command "
zz zz
" to be
sent to remote display device when power on
the switcher
x
= Baud rate (1 ~ 5)
1 - 115200
2 - 57600
3 - 38400
4 - 19200
5 - 9600
zz zz
z
= 0~9, A~F and
up to 20 octets)
/-PU[5]:50 6F 77 65 72 4F 6E
Baudrate: 9600
Power on to send HEX:50 6F 77
65 72 4F 6E
/+PD[
x
]:
zzzz
Set the ASCII “Power Off” command "
zzzz
" to be
sent to remote display device when the switcher
enters standby mode
x
= Baud rate (1 ~ 5)
1 - 115200
2 - 57600
3 - 38400
4 - 19200
5 - 9600
/+PD[5]: ABCDEFG\x\n12