5.3 Display Setting Tab
Automatic Display Control:
Enable or disable the auto display control mode. In auto display control
mode, the unit will automatically perform the operations listed below.
System On:
When the unit detects a source signal input (5V), or receives the
“Wake Up” command, it will
automatically perform the following operations:
1.
Send
Display On
CEC command to the display device.
2.
Send
Display On
->
Delay Time
(default: 10S) ->
Display Input Select
RS232 commands to the
display device.
System Off:
When the unit detects no source signal input and the No Signal Timeout (default: 10 minutes) is on,
or receives “Power Off” command, it will automatically perform the following steps:
1.
Send
Display Off
CEC command to the display device.
2.
Send
Display Off
RS232 command to the display device. This command is sent once by default, or
it can be set to send twice via settings.
3.
After executing the
“
System Off
”
program, the
“
System On
”
can again be triggered.
⚫
No Signal Timeout:
The system will enter standby mode, and the display device will be
automatically shut down when no source signal is detected within the setup time.
⚫
Baud Rate:
Set the baud rate for the display device. It supports 9600, 19200, 38400, 57600,
and 115200.
⚫
Command Format:
The default command format is ASCII; select
“