Reference
Options
Settings
Comments
Edge
With Edge highlighted, the rising or
falling edge of the input signal is used
for the trigger
Source
Channel 1, 2, 3
, or 4
, Ext,
Ext/5, Ext/10
Select the input source as the trigger
signal (See page 114.)
Slope
Rising, Falling
Select to trigger on either the rising
or falling edge of the signal
Mode
Auto, Normal
Select the type of triggering (See
page 113.)
Coupling
AC, DC, Noise Reject, HF
Reject, LF Reject
Selects the components of the trigger
signal applied to the trigger circuitry
(See page 114.)
1
Available only on a 4-channel oscilloscope.
Trigger Frequency Readout
The oscilloscope counts the rate at which triggerable events occur to determine
trigger frequency and displays the frequency in the lower right corner of the
screen.
NOTE.
The trigger frequency readout shows the frequency of events the
oscilloscope might consider to be a trigger, and may be less than the frequency of
the input signal in Pulse Width trigger mode.
Key Points
Mode Options.
The Auto mode (default) forces the oscilloscope to trigger when it
does not detect a trigger within a certain amount of time based on the horizontal
scale setting. You can use this mode in many situations, such as to monitor the
level of a power supply output.
Use the Auto mode to let the acquisition free-run in the absence of a valid trigger.
This mode allows an untriggered, scanning waveform at 100 ms/div or slower
time base settings.
The Normal mode updates displayed waveforms only when the oscilloscope
detects a valid trigger condition. The oscilloscope displays older waveforms until
the oscilloscope replaces them with new ones.
Use the Normal mode when you want to see only valid triggered waveforms.
When you use this mode, the oscilloscope does not display a waveform until
after the
fi
rst trigger.
To perform a Single Sequence acquisition, push the
Single
button.
TPS2000B Series Digital Oscilloscope User Manual
113
Summary of Contents for TPS2012B
Page 1: ...xx TPS2000B Series Digital Storage Oscilloscope ZZZ User Manual P071273302 071 2733 02...
Page 2: ......
Page 3: ...TPS2000B Series Digital Storage Oscilloscope ZZZ User Manual xx www tektronix com 071 2733 02...
Page 8: ......
Page 22: ...Compliance information xiv TPS2000B Series Digital Oscilloscope User Manual...
Page 26: ...Preface xviii TPS2000B Series Digital Oscilloscope User Manual...
Page 40: ...Getting Started 14 TPS2000B Series Digital Oscilloscope User Manual...
Page 93: ...Math FFT TPS2000B Series Digital Oscilloscope User Manual 67...
Page 96: ...Math FFT 70 TPS2000B Series Digital Oscilloscope User Manual...