![Tektronix Tektronix SPG8000 Technical Reference Download Page 75](http://html1.mh-extra.com/html/tektronix/tektronix-spg8000/tektronix-spg8000_technical-reference_1077814075.webp)
Performance veri
fi
cation
Procedures
Be sure you have performed the performance veri
fi
cation preparation before
proceeding. (See page 19,
You can perform performance veri
fi
cation procedures individually, if desired.
AES/EBU serial digital
audio output level test
Perform the following procedure to verify that serial digital audio signals are
output correctly from the 1+2, 3+4, 5+6, 7+8, and DARS connectors. The
procedure is divided into two sections: the
fi
rst checks the AES output signal
amplitude levels using an oscilloscope, and the second checks the AES bar level
outputs using a digital audio monitor.
AES/EBU output signal amplitude level.
1.
Use the 75
Ω
BNC cable and the 75
Ω
feed-through terminator to connect the
AES 1+2 connector on the SPG8000 to the oscilloscope CH1 input as shown
in the following
fi
gure.
Figure 15: Oscilloscope setup for serial digital audio outputs test
SPG8000 Speci
fi
cations and Performance Veri
fi
cation
61