![Tektronix Tektronix SPG8000 Technical Reference Download Page 108](http://html1.mh-extra.com/html/tektronix/tektronix-spg8000/tektronix-spg8000_technical-reference_1077814108.webp)
Performance veri
fi
cation
13.
Use the down (
▼
) arrow button to select
SRAM ADDR BUS 1
.
14.
Use the right (
►
) arrow button to view the
SRAM ADDR BUS
displays
1 through 3.
15.
Check that all buses show
(OK)
for each SRAM ADDR BUS display, and
then record Pass or Fail in the test record.
16.
Use the down (
▼
) arrow button to select
SRAM DATA BUS 1
.
17.
Use the right (
►
) arrow button to view the
SRAM DATA BUS
displays
1 through 3.
18.
Check that all buses show
(OK)
for each SRAM DATA BUS display, and then
record Pass or Fail in the test record.
19.
Use the down (
▼
) arrow button to select
SRAM MEM TEST
, and then
press the
ENTER
button to start the test. The SRAM memory test takes
approximately 60 seconds to complete.
20.
Check that the display reads
SRAM: 0 bad sectors detected
, and then record
Pass or Fail in the test record.
21.
Use the down (
▼
) arrow button to select
DDR2 ADDR BUS 1
.
22.
Use the right (
►
) arrow button to view the
DDR2 ADDR BUS
displays
1 and 2.
23.
Check that all buses show
(OK)
for each DDR2 ADDR BUS display, and
then record Pass or Fail in the test record.
24.
Use the down (
▼
) arrow button to select
DDR2 DATA BUS 1
.
25.
Use the right (
►
) arrow button to view the
DDR2 DATA BUS
displays
1 and 2.
26.
Check that all buses show
(OK)
for each DDR2 DATA BUS display, and then
record Pass or Fail in the test record.
27.
Use the down (
▼
) arrow button to select
DDR2 MEM TEST
, and then
press the
ENTER
button to start the test. The DDR2 memory test takes
approximately 7 seconds to complete.
28.
Check that the display reads
DDR2: 0 errors detected
, and then record Pass
or Fail in the test record.
29.
Press the
BACK
button to exit the
DIAGNOSTICS
submenu.
Exit factory mode.
Exit the factory mode to recover from the memory tests before
continuing with the next veri
fi
cation steps:
30.
Remove and then reattach the power cord to restart the SPG8000.
94
SPG8000 Speci
fi
cations and Performance Veri
fi
cation