Repair
Circuit Board
The circuit board and cable are replaceable
separately.
1.
Remove the transformer as described in
the previous procedure.
2.
To remove the circuit board, cut the cable
tie that secures the cable to the board.
3.
Disconnect the cable from the board.
When reassembling the probe, do not tighten
the new cable tie until you seat the board and
cable in the probe case, to allow enough cable
length for a proper
fi
t.