Service Manual
5-15
Theory of Operation
5
Fusing is provided by two in-line fuses on the AC input line. Overvoltage
protection for the VH, +24 VDC and +5 VDC supplied is provided by a
“crowbar” circuit formed by a Zener diode and an SCR. VH overcurrent is
sensed and regulated by altering the oscillations of the pulse-width-modulator
that generates the voltage. Overheating is detected by a thermostat that also
shuts down the pulse-width-modulator oscillator.