32.
Verify that the hierarchical view is displayed on the MPEG analyzer screen
and that no error messages appear. In addition, verify that the bit rate is
40
Mbps and that the transport stream packet size is
188
bytes.
NOTE.
Ignore Program 3 and PID 120 (0x78) errors in the Navigation view
because these are caused by the original test40.TRP
fi
le.
33.
Press the
Stop
button on the MTX100B.
34.
Close the TS Compliance Analyzer window.
External Clock/Reference
and External Trigger Inputs
This test veri
fi
es that the external clock/reference input (Clock/Ref In) and
external trigger input (Trig In/Out) on the MTX100B are functioning correctly.
Equipment required.
MPEG analyzer
Function generator
Two 50
Ω
BNC cables
Parallel interface cable
test64.TRP
fi
le