KPCI-488LPA-903-01 Rev. B / 

January 2020

 

For safety, instruments and accessories must be used in accordance with the operating instructions. If the instruments or 
accessories are used in a manner not specified in the operating instructions, the protection provided by the equipment may be 
impaired. 

Do not exceed the maximum signal levels of the instruments and accessories. Maximum signal levels are defined in the 
specifications and operating information and shown on the instrument panels, test fixture panels, and switching cards. 

When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard. 

Chassis connections must only be used as shield connections for measuring circuits, NOT as protective earth (safety ground) 
connections. 

If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation requires the use 
of a lid interlock. 

If a 

  screw is present, connect it to protective earth (safety ground) using the wire recommended in the user documentation. 

The 

  symbol on an instrument means caution, risk of hazard. The user must refer to the operating instructions located in the 

user documentation in all cases where the symbol is marked on the instrument. 

The 

  symbol on an instrument means warning, risk of electric shock. Use standard safety precautions to avoid personal 

contact with these voltages. 

The 

  symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns. 

The 

  symbol indicates a connection terminal to the equipment frame. 

If this 

  symbol is on a product, it indicates that mercury is present in the display lamp. Please note that the lamp must be 

properly disposed of according to federal, state, and local laws. 

The 

WARNING

 heading in the user documentation explains hazards that might result in personal injury or death. Always read 

the associated information very carefully before performing the indicated procedure. 

The 

CAUTION

 heading in the user documentation explains hazards that could damage the instrument. Such damage may 

invalidate the warranty. 

The 

CAUTION

 heading with the 

  symbol in the user documentation explains hazards that could result in moderate or minor 

injury or damage the instrument. Always read the associated information very carefully before performing the indicated 
procedure. Damage to the instrument may invalidate the warranty.   

Instrumentation and accessories shall not be connected to humans. 

Before performing any maintenance, disconnect the line cord and all test cables. 

To maintain protection from electric shock and fire, replacement components in mains circuits — including the power 
transformer, test leads, and input jacks — must be purchased from Keithley. Standard fuses with applicable national safety 
approvals may be used if the rating and type are the same. The detachable mains power cord provided with the instrument may 
only be replaced with a similarly rated power cord. Other components that are not safety-related may be purchased from other 
suppliers as long as they are equivalent to the original component (note that selected parts should be purchased only through 
Keithley to maintain accuracy and functionality of the product). If you are unsure about the applicability of a replacement 
component, call a Keithley office for information. 

Unless otherwise noted in product-specific literature, Keithley instruments are designed to operate indoors only, in the following 
environment: Altitude at or below 2,000 m (6,562 ft); temperature 0 °C to 50 °C (32 °F to 122 °F); and pollution degree 1 or 2. 

To clean an instrument, use a cloth dampened with deionized water or mild, water-based cleaner. Clean the exterior of the 
instrument only. Do not apply cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that 
consist of a circuit board with no case or chassis (e.g., a data acquisition board for installation into a computer) should never 
require cleaning if handled according to instructions. If the board becomes contaminated and operation is affected, the board 
should be returned to the factory for proper cleaning/servicing. 

Safety precaution revision as of June 2017. 

Summary of Contents for Keithley KPCI-488LPA

Page 1: ...uments NITM and VISA Virtual Instrument Software Architecture libraries Contact and support information This guide is designed to help you to install your KPCI 488LPA For more detailed information ref...

Page 2: ...pping label Software and hardware installation To download the latest software drivers visit tek com keithley You must install the software driver before you connect the KPCI 488LPA to your computer D...

Page 3: ...ble driver See the Models KPCI 488LPA and KUSB 488B Reference Manual part number KI488 901 01 for the available functions of each driver For LabVIEW and LabWindows CVI support Keithley Instruments rec...

Page 4: ...before touching the KPCI 488LPA card 6 Position the board into the PCI slot you selected 7 Secure the card in place at the rear panel of the system 8 Replace your computer s case In most Microsoft Win...

Page 5: ...your computer with at least two thirds of all devices powered on You can connect devices in a linear configuration star configuration or a combination of the two configurations See the next figures F...

Page 6: ...figuration The GPIB has 24 lines These lines consist of 16 signal lines and eight ground return or shield drain lines The 16 signal lines can be divided into a set of eight parallel 8 bit data transfe...

Page 7: ...O6 15 DIO7 16 DIO8 8 control lines 5 system management lines 5 EOI 9 IFC 10 SRQ 11 ATN 17 REN 3 handshake lines 6 DAV 7 NRFD 8 ground lines 8 NDAC 1 shield drain line 12 SHIELD 7 ground return lines 1...

Page 8: ...ed in all interconnected devices in a known quiescent state SRQ Service Request Used by a device to indicate the need for attention and to request an interruption of the current sequence of events ATN...

Page 9: ...Set the KPCI 488LPA to be a system controller Enable autopolling To launch the configuration utility 1 From Microsoft Windows select Start All Programs 2 From the programs selection select Keithley In...

Page 10: ...ate with any GPIB instrument by writing command strings to your instrument and reading the results Before you launch the diagnostic tool make sure that the KPCI 488LPA is connected to both your comput...

Page 11: ...ool The KI 488 Diagnostic Tool window will open Figure 9 KI 488 Diagnostic Tool To initialize your GPIB interface accessory 1 Select Initialize KI GPIB The Initialize GPIB Interface Board dialog is di...

Page 12: ...nt in the GPIB Command String to Send or Transmit field For example you can send IDN to query the identification of an instrument 3 Under Communications Functions select Send The command string will a...

Page 13: ...ents may be connected to mains These instruments will be marked as category II or higher Unless explicitly allowed in the specifications operating manual and instrument labels do not connect any instr...

Page 14: ...er documentation explains hazards that could damage the instrument Such damage may invalidate the warranty The CAUTION heading with the symbol in the user documentation explains hazards that could res...

Reviews: