background image

16 

071377001 

April

 2022 

The 

CAUTION

 heading in the user documentation explains hazards that could damage the instrument. Such damage may 

invalidate the warranty. 

The 

CAUTION

 heading with the 

  symbol in the user documentation explains hazards that could result in moderate or minor 

injury or damage the instrument. Always read the associated information very carefully before performing the indicated 

procedure. Damage to the instrument may invalidate the warranty.   
Instrumentation and accessories shall not be connected to humans. 
Before performing any maintenance, disconnect the line cord and all test cables. 
To maintain protection from electric shock and fire, replacement components in mains circuits — including the power 

transformer, test leads, and input jacks — must be purchased from Keithley. Standard fuses with applicable national safety 

approvals may be used if the rating and type are the same. The detachable mains power cord provided with the instrument may 

only be replaced with a similarly rated power cord. Other components that are not safety-related may be purchased from other 

suppliers as long as they are equivalent to the original component (note that selected parts should be purchased only through 

Keithley to maintain accuracy and functionality of the product). If you are unsure about the applicability of a replacement 

component, call a Keithley office for information. 
Unless otherwise noted in product-specific literature, Keithley instruments are designed to operate indoors only, in the following 

environment: Altitude at or below 2,000 m (6,562 ft); temperature 0 °C to 50 °C (32 °F to 122 °F); and pollution degree 1 or 2. 
To clean an instrument, use a cloth dampened with deionized water or mild, water-based cleaner. Clean the exterior of the 

instrument only. Do not apply cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that 

consist of a circuit board with no case or chassis (e.g., a data acquisition board for installation into a computer) should never 

require cleaning if handled according to instructions. If the board becomes contaminated and operation is affected, the board 

should be returned to the factory for proper cleaning/servicing. 
Safety precaution revision as of June 2018. 

Summary of Contents for Keithley 2306-LAN

Page 1: ...y detects the network speed Figure 1 Model 2306 LAN connection location Contact your network administrator to confirm your specific network requirements before setting up a LAN connection If you have...

Page 2: ...rk Contact your corporate IT department for permission before you connect the 2306 LAN to a corporate network When the 2306 LAN is shipped the IP configuration is set to manual and is set to the follo...

Page 3: ...is is the instrument default 192 168 0 2 Figure 3 Model 2306 LAN configure computer Check communication settings Before configuring the LAN you can check the communications settings on the instrument...

Page 4: ...mask port and LAN configuration on the instrument from the front panel Contact your corporate information technology IT department to secure a valid IP address for the instrument when placing the inst...

Page 5: ...take effect and return to the main menu LAN configuration through a computer You will need to download the 2306 LAN Configuration Tool from the Product Support and Downloads web page This tool provide...

Page 6: ...uration setting Description 1 Local IP address of your computer 2 Instrument serial number 3 Instrument MAC address 4 Instrument IP address 5 Port 5025 is the default 6 Select Clear to clear all of th...

Page 7: ...ols to communicate with the 2306 LAN instrument Port number Protocol 1024 VXI 11 5025 Raw socket You can only use one remote interface at a time Although multiple ethernet connections to the instrumen...

Page 8: ...timeout value to 60 seconds system_dmm TimeoutMilliseconds 60000 system_dmm SendEndEnabled true system_dmm TerminationCharacterEnabled true return character system_dmm TerminationCharacter 0xa system_...

Page 9: ...CP port 5025 ipe new IPEndPoint ip 5025 clientSocket new Socket AddressFamily InterNetwork SocketType Stream ProtocolType Tcp Connect to instrument through LAN clientSocket Connect ipe send message st...

Page 10: ...ou already have NI software such as LabVIEWTM or LabWindowsTM installed you have a valid license that can be used with Keithley drivers and application software If you do not have NI software installe...

Page 11: ...ng figure indicate the items that need to be configured TCPIPO Send End En Suppress End En TermChar En TermChar Figure 8 Model 2306 LAN NI VISA programming example Use a semicolon after each command w...

Page 12: ...ed to download the firmware you want to install on your Model 2306 LAN instrument from the Product Support and Downloads web page Go to LAN configuration through a computer on page 5 for more informat...

Page 13: ...192 168 0 3 as shown in the following figure Figure 11 Upgrade LAN firmware 4 Select Scan The IP information of the instrument is displayed the default IP address is 192 168 0 2 5 Select Select Fw to...

Page 14: ...at the correct ethernet configuration information for the card was used during the setup procedure Verify that the network card in the computer is enabled Verify that the IP address of the instrument...

Page 15: ...will be marked as category II or higher Unless explicitly allowed in the specifications operating manual and instrument labels do not connect any instrument to mains Exercise extreme caution when a s...

Page 16: ...components that are not safety related may be purchased from other suppliers as long as they are equivalent to the original component note that selected parts should be purchased only through Keithley...

Reviews: