Examples
K1297-G20 Monitor User Manual
67
Starting Measurements
The autoconfiguration feature automatically defines an online data
source (
Scenario
) and generates an online measurement scenario as
a pipeline which contains several branches for individual measurement
tasks. An online data source is a group of logical links. A logical link
consists of a channel and a channel data interpretation rule (assigned
protocol).
The settings for each data source, as detected by the autoconfiguration
feature, are displayed in the expanded left part of the window under
List of Scenarios
(to expand, click “
+
”):
The following information is provided:
[1]D(Rx):16:-:64 [Whibisup.stk]
(example)
1:
first
board
A:
port MON A
(Rx)
direction, here: Receive
16:-:64
timeslot 16, no subchannel (
-
), with 64 kbit/s
Whibisup.stk
detected protocol setting, here: the stack for SS#7
White Book according to ITU-T