ACCESSORIES
Replacem ent Parts
GRATICULES
38 6 -3 9 5 Unruled, for Type 3 1 0 ............................
1.00
38 6 -3 1 2 Unruled, for Type 3 1 5 ............................
1.00
3 3 1 -0 2 7 Quarter-inch divisions,
8
divisions verti
cally, 10 horizontally, for Type 310 and
36 0 ..............................................................
1.50
33 1 -0 0 5 Quarter-inch divisions,
8
divisions verti
cally, 10 horizontally, for Type 3 1 5 . . .
1.50
3 8 6 -3 2 6 Unruled, fits Types 5 1 1A, 512, 513,
514, 5 1 4A, 524D , 5 2 4 A D ......................
1.00
33 1 -0 2 3 Centimeter ruling, 4 centimeters verti
cally, 10 horizontally, for Types 51 1 A
with 5CP CRT..............................................
1.50
33 1 -0 2 4 Centimeter ruling, 4 vertically, 10 hori
zontally, for Type 514 with 5CP CRT,
513 with T51PA CRT..................................
1.50
33 1 -0 0 6 Centimeter ruling,
6
centimeters verti
cally, 10 horizontally, for Type 512
with 5CP CRT, Types 514A , 524D,
524AD and Type 5 1 1A with 5ABP CRT
1.50
3 3 1-01 0 Centimeter ruling,
8
centimeters verti
cally, 10 horizontally, for Type 512
with 5ABP CRT...........................................
1.50
33 1 -0 0 7 Centimeter ruling, 4 centimeters verti
cally,
8
horizontally, for Type 513 with
5XP C R T.......................................................
1.50
3 3 1-00 8 Centimeter ruling, 4 centimeters verti
cally,
8
horizontally, for Type 5 1 7 . . . .
9.50
3 3 1 -0 0 9 TV RMA style ruling for percentage
measurements, for Types 524D and
524AD
.......................................................
1.50
3 3 1-03 5 Ruling in percentages, — 40 to + 1 0 0 ,
for Type 5 2 5 .............. ..............................
1.50
33 1 -0 2 6 Centimeter ruling,
8
centimeter verti
cally, 10 horizontally, for Type 5 3 2 . . .
1.50
3 3 1 -0 1 6 Centimeter ruling,
6
centimeters verti
cally, 10 horizontally, for Types 531
and 5 3 5 .......................................................
1.50
3 3 1 -0 2 5 Centimeter ruling, 4 centimeters verti
cally, 10 horizontally, for Types 541
and 5 4 5 .......................................................
1.50
33 1 -0 2 8 Division ruling, 10 divisions vertically,
10 horizontally, for Type 5 7 0 .................
1.50
CATHODE-RAY-TUBE LIGHT FILTERS
378-511 3" Amber (for Type 310 and 3 6 0 ) .................50
3 7 8 -5 0 9 3 " Green (for Type 310 and 3 6 0 ) .................50
3 7 8 -5 1 0 3 " Blue (for Type 310 and 3 6 0 ) ................... 50
3 7 8 -5 0 6 3 " Amber (for Type 3 1 5 D ) ............................ 50
3 7 8 -5 0 5
3 "
Green (for Type 315 D ) ............................. 50
3 7 8 -5 0 7 3 " Blue (for Type 3 1 5 D ) ..................................50
378-501 (F 510 -3) 5 " Am ber.........................................90
3 7 8 -5 0 3 (F 51 0 -5 ) 5 " G reen ........................................... 90
3 7 8 -5 0 4 (F 510 -6) 5 " Blue..............................................90
AC POW ER CORDS
161-00 4 (COP 1 6 -8) No. 16 wire,
8
' long____
2.40
16 1-003 (COP 1 8 -1 ) No. 18 wire, 1' long..................85
161-001 (COP 1 8 -8) No. 18 wire,
8
# lo ng____
1.50
161-00 7 (COP 18 -8) Right an g le ........................
1.50
PATCH CORDS
Two series of patch cords are available. The Series-PC
patch cords have a male and female banana-type con
nector on each end for the purpose of “ stacking” the
connectors. The Series-W530 patch cords have single
banana plugs on each end. Both series are available in
red or black and in 18 inch and
6
inch lengths.
01 2 -0 1 3 Type W -5 3 0 B , black, 1 8 " ......................
1.00
01 2 -0 2 3 Type PC-
6
B, black,
6
" ...........................
1.25
0 1 2 -0 2 4 Type PC-
6
R, red,
6
" ................................
1.25
0 1 2-02 8 Type W -531B , black,
6
" ........................
1.00
0 1 2 -0 2 9 Type W -531R , red,
6
" ...........................
1.00
012-031 Type PC-18R, red, 1 8 " ...........................
1.25
SPECIAL CORDS A N D LEADS
0 1 2 -0 0 7 (W 112R ) Red output lead for Type 112
1.00
0 1 2-00 8 (W 11 2B ) Black output lead for Type
1 1 2
...........................................................
1.00
01 2 -0 0 9 (W 1 2 2 ) Battery power lead for Type
1 2 2 ..............................................................
7.50
0 1 2 -0 1 4 (W 13 0B ) Black output lead for Type
1 3 0 ..............................................................
1.00
0 1 2 -0 1 5 (W 130R ) Red output lead for Type 130
1.00
0 1 2 -0 1 6 (W 1 6 0 -2 0 )
2 0
" inter-unit power cable
for Type 160-Series..................................
2.00
0 1 2 -0 1 7 (W 1 6 0 -1 0 )
1 0
" inter-unit power cable
for Type 160-Series..................................
2.00
0 1 2-01 2 (W 5 1 7 ) Inter-unit power cable for
Type 5 1 7 .....................................................
9.50
MISCELLANEOUS
0 1 1-01 8 Attenuator unit, for Type 1 9 0 A .............. 19.00
0 1 0 -0 0 3 P93C Probe, for Type 1 3 0 ......................
2.00
01 4 -0 0 3 FM
1
24 Mounting frame, for Type 124 .
5.00
T e k t r o n i x ,
I n c
,
A -l 1
Summary of Contents for 502 series
Page 2: ......
Page 6: ......
Page 7: ...Fig 1 1 Type 502 Oscilloscope with accessories ...
Page 8: ......
Page 36: ......
Page 50: ......
Page 77: ...0 0 TYPE 502 OSCILLOSCOPE A BLOCK DIAGRAM ...
Page 79: ...INPUT A M PLIFIE R SECOND D R IV E R O UTPUT A M PLIFIE R C F S AM PLIFIE R X 10 X 100 ...
Page 82: ...V722 type 502 o s c illo s c o p e HEATER WIRING DIAGRAM A POWER SUPPLY ...
Page 90: ...M ILLE RRUNUP CIRCU IT 350 V 2 3 M ILUSEC TIME BASE GENERATOR 12 8 58 ...
Page 94: ...CALIBRATOR MULTIVIBRATOR TYPE 502 OSCILLOSCOPE A ...