Calibration—
Type 1A1
18. Check Channel 1 Signal Out Amplifier
Gain
a. Test equipment setup, with connections made at com
pletion of step 18d, is shown in Fig. 7-19.
b. Connect a 18-inch 50-ohm cable from the CH 1 SIG
NAL OUT connector to the Channel 2 INPUT connector.
c. Connect a 42-inch 50-ohm cable from the oscilloscope
Calibrator Output connector to the Channel 1 INPUT con
nector.
d. Adjust the oscilloscope Triggering Level control to
obtain a stable display.
e. CHECK— That the peak-to-peak amplitude of the dis
play is two cm [100 mV), ± 2 mm (see Fig. 7-20). This is a
gain of 1 0 X , ± 1 0 % .
Fie, 7-Jl. Equipmtnl »tup for stop 19.
Control Settings
Type 547 Oscilloscope
Amplitude Calibrator
lOmVolts
Type 1A1
Horizontal Display
B
MODE
CH 2
Sweep Magnifier
X I Off
POSITION
Single Sweep Switch
Normal
(both channels)
Near midrange
Triggering Level
Near 0 and pushed in
PULL FOR INVERT
Triggering Source
Norm Int
(both channels)
Normal or in
Triggering Coupling
AC
VARIABLE VOLTS/CM
Triggering Slope
+
(both channels)
CALIB
Triggering Mode
Auto Stability
VOLTS/CM (Chan
.005
Timc/Cm
.5 msec
nel 1)
Variable [Timc/Cm)
Calibrated
VOLTS/CM (Chan
Horizontal Position
Trace positioned to
nel 2)
.5
start at left graticule
INPUT SELECTOR
line
(both channels)
AC
7-18