ACQUIRE
THS710A, THS720A, THS730A & THS720P User Manual
3–7
Acquire Menu in Meter Mode
METER
ACQUIRE
Acquire Mode
Sample
Peak Detect
Average
Rel
D
On (Reset
D
)
Off
Key Points
Acquisition Modes.
The data logger compresses a sequence of meter
measurements into a point and then plots a series of those points to
form a graph. The acquisition mode determines how the graph is
calculated:
H
For each point, Sample displays the first meter measurement
from the sequence.
H
Peak Detect displays a column representing the maximum and
minimum meter measurements during the sequence.
H
Average displays the average of all meter measurements during
the sequence.
Rel
D
Measurements.
Rel
D
acquires a new baseline value for
subsequent DMM measurements. Use Rel
D
to store the current
DMM value and then measure the relative change from that value.
When you turn off Rel
D,
the baseline value resets to zero.
Summary of Contents for 070-9731-05
Page 12: ...Getting Started ...
Page 13: ......
Page 24: ...Operating Basics ...
Page 25: ......
Page 59: ...General Purpose Application Examples 2 34 THS710A THS720A THS730A THS720P User Manual ...
Page 79: ...Power Measurement Application Examples 2 54 THS710A THS720A THS730A THS720P User Manual ...
Page 80: ...Reference ...
Page 81: ......
Page 83: ...Introduction to Reference 3 2 THS710A THS720A THS730A THS720P User Manual ...
Page 155: ...VERTICAL Controls 3 74 THS710A THS720A THS730A THS720P User Manual ...
Page 156: ...Appendices ...
Page 157: ......
Page 181: ...Appendix B Factory Setup B 4 THS710A THS720A THS730A THS720P User Manual ...
Page 187: ...Appendix C Accessories C 6 THS710A THS720A THS730A THS720P User Manual ...
Page 211: ...Appendix D Performance Verification D 24 THS710A THS720A THS730A THS720P User Manual ...
Page 213: ...Appendix E General Care and Cleaning E 2 THS710A THS720A THS730A THS720P User Manual ...
Page 214: ...Glossary and Index ...
Page 215: ......