Control Panel – TEKNA TCK 

 

 

 

 

 

Access to the programming menu 

 

 

 

When pressed during the pump operation phase, it cyclically displays the programmed values on the 

display; When pressed at the same time as the 

  

 keys, it increases or lowers a value 

dependent on the selected operating mode. During programming it carries out an “enter” function, 
meaning that it confirms entry to the various menu levels and modifications within the same. 

 

 

 

Starts and stops the pump. In the event of a level alarm (alarm function only), flow alarm and active 
memory alarm, it deactivates the signal on the display. 

 

 

 

Used to “exit” the various menu levels. Before definitively exiting the programming phase, you will be 
asked if you wish to save any changes. 

 

 

 

Used to run upwards through the menu or increase the numerical values to be changed. Can be used 
to start dosage in Batch mode 

 

 

 

Used to run downwards through the menu, or decrease the numerical values to be changed. 

 

 

 

Flashing green LED during dosage 

 

 

 

Red LED that lights up in various alarm situations 

 

Electrical connections 

Output relay 

Not connected 

-Remote control input (start-stop) 
-Pause signal input 

Trigger signal input 

10

Flow sensor input 

B

Input level control 

B

Summary of Contents for TCK

Page 1: ...nction only flow alarm and active memory alarm it deactivates the signal on the display Used to exit the various menu levels Before definitively exiting the programming phase you will be asked if you wish to save any changes Used to run upwards through the menu or increase the numerical values to be changed Can be used to start dosage in Batch mode Used to run downwards through the menu or decreas...

Page 2: ...nute of no activity Any data entered in these circumstances will not be saved The key can be used to exit the various programming levels Upon exiting programming the display will show Exit Exit No Save Save to confirm the selection Pump Funtions Configuration Pump Functions Pump Functions Timer PROG Pump Functions Weekly Timer Manual N Open Paragraph 1 Paragraph 4 Paragraph 5 Paragraph 6 Paragraph...

Page 3: ...nd the flow can only be regulated manually by pressing the keys at the same time in order to increase the flow or the keys to decrease it Display during Operation Display during Setting MODE key MAN F F F Lev Stop P100 Operating mode Man Manual Alarms and statuses Lev Level alarm Flw Flow alarms FLOW sensor status Pump status Empty pump in start Stop pump stationary Paus pump in pause Current dosa...

Page 4: ...ed by pressing the key in Off mode the relay is not switched off open and in after mode the relay closes when dosage is activated and remains closed once dosage is completed for the time in seconds set using the keys and then confirmed by pressing the key In before mode the relay closes before the dosage activation time for the time in seconds set using the keys and then confirmed by pressing the ...

Page 5: ... the pump doses a quantity that can be programmed in ml It is possible to set a delay time before the dosing Delay and the interval between subsequent dosings Interv as illustrated in the diagram By setting for example an Interval time 0 a system is obtained in which the programmed quantity is dosed after each TRIGGER signal with any delay that has been set It is possible to start the dosing by pr...

Page 6: ...sings Interval as illustrated in the diagram The Delay and Interval times are in dd hh mm days hours minutes The Pause input can be programmed in three different modes 1 FreezeTime when the pause is activated the system cuts out the current time count and restarts it when the pause is deactivated 2 Pause Dosing with the pause activated the system continues to count time the and stops the dosing 3 ...

Page 7: ...ion if open default or closed Changes can be made by pressing the key then using the keys to set the new value Press to confirm and return to the main menu Paragraph 6 Flow rate Calibration Programming Operation Pump Calibration Pump Calibration Automatic Cal Automatic Cal Automatic Cal Pump Calibration 0 23 cc stroke cc stroke 0 23 Start 100 strok Strokes 100 ml 20 Manual PROG Pump Calibration Au...

Page 8: ...ord Password 0000 PROG By entering the password you can enter the programming menu and see all the set values The password will be requested whenever you seek to modify them The flashing line indicates the number than can be modified Use the key to select the number from 1 to 9 and the key to select the number to be modified Confirm by pressing the key By setting 0000 default the password is elimi...

Page 9: ...menu Paragraph 12 Setting the Pause Programming Operation Paus N Aperto PROG Configurazione The pump can be paused by remote input The factory setting is Normally Open Changes can be made by pressing the key then using the keys to set the new value N OPEN or N CLOSED Press to confirm and return to the main menu Display contrast adjustment For adjusting the display contrast keep the key pressed and...

Reviews: