Function of the TEKA-LMD 508 

The  TEKA  -  LMD  508  filter  equipment  is  primarily  used  for  localised  extraction  of  dust,  smoke 
particles and gases. For this purpose, the unit is equipped with two flexible extractor hoses, or an 
extractor fitting that is appropriate to the application. 

Limits of application: 

welding fumes with oil mist, aluminium dust, grinding dust, extraction of metallic dust, water etc. 

(If you are uncertain, please contact the manufacturer!) 

The polluted air is gathered in by the extractor fitting and transported to the filter equipment through 
the extractor hose. Coarse dust particles are then filtered out in the prefilter matting (Pos.13). The 
following  particle  filter  (fine  filter,  Pos.14)  extracts  the  extremely  fine  smoke  particles  with  an 
efficiency  of  better  than  99%.  In  a  further  filter  stage,  the  activated-carbon  cassette  (Pos.15) 
adsorbs the  gaseous pollutants. The filtered air is then sucked in by the turbines and returned  to 
the air in the environment through the exhaust mesh on the sound absorption module. 
The  LMD  508  filter  unit  can  be  connected  to  an  external  filter  monitoring  through  the  Harting  or 
Sub-D 9-pin socket (Pos.21) (available as an option). 

 

Warning:

 

As  soon  as  the  airflow  resistance  of  the  filter  has  increased  to  the  point  where  the  suction  force 
decreases,  the  filter  must  be  replaced,  because  it  is  clogged  with  the  extracted  dust  and  smoke 
particles. 

(see  Section  7.1:  “Replacing  the  prefilter  matting”,  Section  7.2:  “Replacing  the  particle  filter”

  and 

Section 7.3: “Replacing the activated-carbon cassette”)

 

 
 

4  Safety instructions 

When using electrical equipment, the following basic safety rules must be observed, for protection 
against electric shock, injury, or fire hazards. 

  Before using the equipment, read and observe these instructions! 

  Keep the operating and maintenance instructions in a safe place! 

  Never use the equipment to extract easily inflammable or explosive gases! 

  Do not employ the unit for setting it in explosive zones, e.g. zone 0, zone 1, zone 2, zone 20, 

zone 21, zone 22! 

  Do  not  employ  the  unit  for  sucking  off  burning  or  glowing  materials,  e.g.  cigarettes,  matches, 

metallic types of dust and/or splinters, paper, cleaning cloths, etc.! 

  Do not employ the unit for sucking off burning and/or inflammatory materials, e.g. oils and/or oil 

mist, fats, parting agent (e.g. silicone spray), cleaning agent, etc.!  

  Never use the equipment for the extraction of corrosive substances! 

  Never use the equipment to suck up any kind of liquid! 

  Do not use the equipment for the extraction of organic substances without written approval from 

the manufacturer! 

  Protect the connectors from heat, moisture, oil, and sharp edges! 

  Keep to the permitted supply voltage! (Observe the data on the nameplate!) 

  Use only TEKA replacement parts! 

 

Summary of Contents for LMD 508

Page 1: ...nstructions Type TEKA LMD 508 TEKA Absaug und Entsorgungs technologie GmbH Industriestra e 13 D 46342 Velen Postfach 1137 D 46334 Velen Tel 49 0 2863 9282 0 Fax 49 0 2863 9282 72 E Mail sales teka eu...

Page 2: ...mmissioning 6 5 1 Attaching the extractor fittings 6 5 2 Electrical connection of the unit 7 6 Operation of the system 8 7 Maintenance 8 7 1 Replacing the prefilter matting 9 7 2 Replacing the particl...

Page 3: ...Filter door Ventilator housing Ventilator door Castor Castor with brake Twist lock fastener Lifting mechanism Pos 11 Pos 13 Pos 14 Pos 15 Pos 16 Pos 17 Pos 18 Pos 19 Locking screw for the lifting mec...

Page 4: ...complete volume of air in the workshop is replaced However this method only achieves a small reduction in the level of pollution within the breathing space of the user The same applies to the so call...

Page 5: ...to the point where the suction force decreases the filter must be replaced because it is clogged with the extracted dust and smoke particles see Section 7 1 Replacing the prefilter matting Section 7...

Page 6: ...possible damage The unit must not be used if the mains supply cable is not in perfect condition Do not use the filter unit if one or more of its components are faulty missing or damaged In any of the...

Page 7: ...e motor speed of the turbine 3 4 Filter alarm Floating output normal open contact for interpretation of the warn alarm Filter alarm 5 6 Operation control Floating output normal open contact for interp...

Page 8: ...ce decreases the particle filter Pos 14 must be replaced because it is clogged with the extracted dust and smoke particles see Section 7 2 Replacing the particle filter The activated carbon cassette P...

Page 9: ...14 Use the fixing screw Pos 11 to raise the lifting mechanism Pos 10 so that the particle filter Pos 14 fits tightly underneath the equipment cover Pos 2 Close the filter door Pos 4 Connect the filte...

Page 10: ...activated carbon cassettes Use the fixing screw Pos 11 to raise the lifting mechanism Pos 10 so that the particle filter Pos 14 fits tightly underneath the equipment cover Pos 2 Close the filter door...

Page 11: ...e Ph 1 Frequency Hz 50 Motor power kW 1 2 Max airflow volume m h 320 Max partial vacuum Pa 21000 Enclosure type IP 54 ISO class F Operating voltage V 230 Duty cycle 100 Width x depth x height mm 365 x...

Page 12: ...article filter Pos 14 Activated carbon cassette Pos 15 Activated carbon pouring Turbine 1 2kW with elektronic Castor Pos 11 Castor with brake Pos 12 Suction hose length 2 5m NW45 with air intake Sucti...

Page 13: ...ng directives Machinery directive 2006 42 EG Electromagnetic compatibility 2014 30 EU Pressure equipment device 97 23 EG Low voltage directive 2006 95 EG Applied harmonised standards DIN EN 349 DIN EN...

Reviews: