Shine Plus Maxi Digi
User Manual
Version
0.0.9
Page 18 of 64
effect. In CV116 the flickering period is given for the flickering lamp
effect. The Defective Neon effects repetition time can be set in
CV117.
The effects are configured for each of the outputs in CVs 136-152. In
the current firmware version (V3) the CVs has to be programmed
with the following values:
0
Continuous outputs
1
Fade effect
2
Fluorescent (neon) effect
3
Flickering effect
4
Defective Neon effects
The modules are delivered with the outputs configured for
continuous operation (CV120 thru CV135 are set to value 0 ).
A pseudo random sequence generator function is also available,
activating this for an output, it will switch on and off without the
need of switching on and off a function. To select an output for the
random sequence, the value of 128 must be added to the effect values
(values in the range of 0-4) given in CV136-152. The switching
period of the random sequence is defined in CV115 in the range of 1-
255 seconds. As a result, after each elapse of the random period, the
state of the outputs which have the random effect activated will
change to a new on/off state, which is random based. It gives a very
realistic effect to a carriage, when rolling on the track, and some of
the compartment lights are switched on, or off.
The number of random states increases dramatically with the
increase of the outputs selected for this function. We
recommend the use of 2-4 of the outputs with the random