Fn_16:
Direct Start / Scanning / Reset Options
xxx0: Direct start enable when remote RUN command is ON
xxx1: Direct start disable when remote RUN command is ON
xx0x: Reset effective only if remote RUN command is OFF
xx1x: Reset effective regardless of the remote RUN command condition
00xx: TM2 terminal will scan 10 times
01xx: TM2 terminal will scan 5 times
10xx: TM2 terminal will scan 3 times
11xx: TM2 terminal will scan once
Note:
1. When (Fn_16) is set at (xxx1) and the control mode is set for terminal 2 control (Fn_10), the
T-verter cannot start if the RUN switch is on when the power is engaged. The “STP1” LED
will flash. On the Keypad the RUN switch must be turned OFF and ON again, in order for the
T-verter to start.
2. Scanning the input signals at TM2 on terminals (3) (4) (5) (6) (7) (8) (9)
(FWD) (REV) (SP1) (SP2) (SP3) (RESET) are set at (Fn_16). If TM2 detects the same input
signals for the programmed number of times in a row, the T-verter will treat the signal as a
normal signal and execute it.
On the other hand, if TM2 detects the same input signals that are less than the number of times
programmed, TM2 will interpret the signal as noise. Remark: The scan time is 2 ms
Fn_17~Fn_23 : Pre-Set Speeds and Timer Controls
Fn_17:
Pre-Set
Speed
1:
0.01
Hz
~
0-400
Hz
Fn_18:
Pre-Set
Speed
2:
0.01
Hz
~
0-400
Hz
Fn_19:
Pre-Set
Speed
3:
0.01
Hz
~
0-400
Hz
Fn_20:
Pre-Set
Speed
4:
0.01
Hz
~
0-400
Hz
Fn_21:
Pre-Set
Speed
5:
0.01
Hz
~
0-400
Hz
Fn_22:
Pre-Set
Speed
6:
0.01
Hz
~
0-400
Hz
Fn_23:
Pre-Set
Speed
7:
0.01
Hz
~
0-400
Hz