EV Inverter Operating Manual
___________________________________________________________________________
TECO
– Westinghouse Motor Company 34
Fig 11.4c setting:
Fig 11.4d setting:
F17
F18
F19
F20
F17
F18
F19
F20
E 100% 020% 001
000
F 100% 050% 001
001
F21 Multi function output RY1
000: Run
001: Frequency reached (Preset target frequency ± F23)
002: Frequency reached (Preset output frequency level (F22) ±F23)
003: Frequency detection (>F22)
004: Frequency detection (<F22)
005: Fault output
006: Auto restart
007: Momentary power loss
008: Emergency stop (E.S.)
009: Base block(b.b.)
010: Motor overload protection
011: Inverter overload protection
012:
Not used
013: Power on
014: Communication error
015: Output current detection (>F24)
F22 Preset output frequency
target
00.0 - 200Hz
F23 Target frequency
detection range
00.0 - 30Hz
Upper frequency limit
(F07=60.0)
Upper frequency limit
(F07=60.0)
Hz
V
60Hz
30Hz
0Hz
E
2V
(7.2mA)
10V
(20mA)
Bias
-000%
-020%
-100%
Fig 11.4c
Hz
V
60Hz
30Hz
0Hz
F
5V
(12mA)
10V
(20mA)
Bias
-000%
-050%
-100%
Fig 11.4d