6 ALARM MANAGEMENT, BUZZER
6.1
STORAGE OF DATA/ERRORS
the appliance electronic controller is equipped with a system
of acoustic and visual signals to indicate the intervention of
safety devices. the table below gives a list of the alarms
shown on the panel display
6.2
THE SOFTWARE CONTROLS THE FOLLOWING ALARMS
ALL 01
Evaporator probe alarm
Cause:
exit from operating range (-50°c / +100°c) for over
30 seconds.
Probe is defective (rePlace Probe).
Beeper:
activated (3 seconds, then a pause of 30 seconds)
until the mute button is pressed.
Display:
alternates message “all 01” with standard display
Reset:
automatically resets only when probe reading has
returned to normal.
ALL 02
Core probe alarm
Cause:
exit from operating range (-50°c / +100°c) for
more than 30 seconds during current chilling cycle
by temperature.
Effect:
interruption of current chilling cycle by tempera-
ture and automatic start-up of timed chilling cycle.
chilling by temperature push-button disabled.
Probe is defective (rePlace Probe).
Beeper:
activated (3 seconds, then a pause of 30 seconds)
until the mute button is pressed.
Display:
alternates message “all 02” with standard display
Alarm relay:
not activated.
Reset:
Press the mute push-button (with beeper off ).
resets automatically if probe value returns to nor-
mal, but cycle remains in timed mode. alternati-
vely, switch off the panel then turn it back on
(stand-by).
ALL 03
Cell probe alarm
Cause:
exit from operating range (-50°c / +100°c) for over
30 seconds.
Probe is defective (rePlace Probe).
Effect:
any current chilling cycle is interrupted.
if a storage phase is in progress, the compressor
and the fan set to stand-by status.
when the appliance is in stop status, press start to
set the compressor and fan to stand by.
Beeper:
activated (3 seconds, then a pause of 30 seconds)
until the mute button is pressed.
Display:
alternates message “all 03” with standard display
Reset:
automatically resets only when probe reading has
returned to normal.
ALL 04
Optional probe alarm
(disabled if no probe is connected)
ALL 05
Input SW2
(door microswitch alarm)
Cause:
input active for more than 5 minutes with ap-
pliance in start status.
Door open (close door) microswitch fault (replace
the microswitch)
Beeper:
activated (3 seconds, then a pause of 30 seconds)
until the mute button is pressed.
Display:
alternates message “all 05” with standard display
Reset:
Press the mute push-button (with beeper off ).
automatically resets if input value returns to nor-
mal alternatively, switch off the panel then turn it
back on (stand-by).
ALL 06
Input SW1 alarm
(Press. max for all models)
(Thermal-magnetic switch for MOD.
r
)
(Oil diff. pressure switch for MOD.
t
)
Cause:
input active for more than 5 seconds
Effect:
sets the appliance to stoP.
reset the max. pressure switch, thermal-magnetic
switch or differential pressure switch.
Beeper:
activated (3 seconds, then a pause of 30 seconds)
until the mute button is pressed.
Display:
alternates message “all 06” with standard display
Reset:
Press the mute push-button (with beeper off ) with
no alarm cause displayed