blast chiller istrUction c-2003
06/2011
2. INSTALLATION
2.1
DATA PLATE INFORMATION
•
check that the data specified on the plate correspond to the
characteristics of the power supply (V, kw, hz, no. phases and
power available).
•
the dataplate with appliance specifications is located at the
rear exterior of the machine and/or on the electrical boards.
the set-up of individual
units and the installation of
condensers are subject to
the fire-safety regulations of
the country in which the
machine is installed; seek all
necessary advice from the
local fire-fighting authori-
ties.
bear in mind that the intervention of safety valves or plug
fuses in the refrigerating circuit will lead to the immediate
discharge of refrigerant into the environment.
2.2
REMARKS / MALFUNCTION’S CLAIMS
in case of machine malfunctioning and claim on blast chil-
lers delivered in the following way :
•
Assembled (MOD.
w
)
we ask you to indicate to the dealer / service: machine
model, machine code number and apparatus serial number.
these information are written on the registration label, in-
stalled on the back of machine and inside the door.
•
Disassembled (MOD.
t
)
we ask you to indicate to the dealer / service: machine
model, machine code number and apparatus serial number.
these information are written on the registration label, in-
stalled on top of the control panel.
2.3
POSITIONING
•
the machine must be installed and commissioned in com-
plete compliance with safety regulations, procedures and
standing laws.
•
the installation technician bears the responsibility of ensu-
ring compliance with fire safety requirements; seek all ne-
cessary advice from the local fire-fighting authorities.
•
Position the machine in the allocated site.
•
adjust the machine feet until the appliance is perfectly level.
in the case of particularly heavy equipment, use appropriate
lifting means (fig. a - cap. 1.3).
•
if the appliance is not perfectly level, correct operation and
condensate flow-off will not be assured.
Avoid
•
direct exposure to sunlight;
•
closed sites with high temperatures and poor air circulation;
•
installing the machine near sources of heat.
2.4
AMBIENT TEMPERATURE AND AIR CIRCULATION
for air-cooled appliances, the maximum ambient tempera-
ture for operation is 32°c. correct operation cannot be gua-
ranteed at higher temperatures.
the machine may operate safely to a maximum temperature
of 38°c.
remote condensing units must be installed in special rooms
or outdoors, protected against direct sunlight by a shelter or
roof structure (at the cost of the purchaser).
sufficient air circulation must be guaranteed at all times.
2.5
ELECTRICAL CONNECTIONS
a dedicated thermal-magnetic circuit breaker compliant
with established regulations must be installed on the ap-
pliance power line.
•
connected electrical cables must correspond to the techni-
cal data (as specified on electrical drawings provided by the
installation technician).
connect the earthing conductor to an efficient earthing sy-
stem.
The manufacturer declines all liability and guarantee obli-
gations in the event of injury to persons or damage to
equipment and objects due to incorrect installation and/or
failure to comply with standing installation regulations.
2.5.1 Connecting the appliance to the power supply
in the event of damage to the power supply cable on the ap-
pliance, have the cable replaced only by a qualified electri-
cian to avoid any risk of personal injury
THESE OPERATIONS MUST BE
PERFORMED BY A CERTIFIED
INSTALLATION TECHNICIAN ONLY
Serial
~
Hz
A
W
kg
W
W
W
38Ø-4ØØ/3N
5Ø
1Ø
3ØØØ
Machine model
AX8
ØØØ 1Ø3 Ø3213
R4Ø4 A
2.2
CLASS T
11
IP 21