JULY-2014
117
REMARK
A leak observed on a circuit is often due to:
•
O rings that are missing, damaged or fitted incorrectly,
• the presence of foreign bodies,
• clamps that are not tight.
6.5.4.2
Removing and fitting
pipes
IMPORTANT
The following instructions must be observed:
• Always ensure it is clean.
• The
pipes must always be fitted so that in all circumstances:
◊
they are not subject to tension.
◊
there is no compression of short lengths.
◊
there are no external mechanical forces applied to the hydraulic pipes.
◊
avoid rubbing, attach them correctly. If necessary, protect the pipes with protective sheaths
protect sharp edges.
◊
the bend radii do not cause the pipes to be pinched.
6.5.5 - AXLES
IMPORTANT
Have your axle assembly serviced regularly by a trained specialist.
6.5.6 - TYRES
Do not work on
tyres unless you have the required tools and experience. If in doubt consult qualified personnel.
CAUTION
Incorrect assembly can seriously jeopardize your safety.
IMPORTANT
The installation of tyres other than the ones recommended by the manufacturer is not allowed
IMPORTANT
• Regularly check the
inflation pressure when the
tyres are cold.
• Never reduce the
inflation pressure when hot as the it may then be too low after cooling.
• 0.1 bar is the maximum difference in pressure allowed between tyres on the same axle.
Refer to the "
t
yres
"
paragraph in chapter
COMMISSIONING THE MACHINE
•
Before fitting a tyre,
◊
eliminate any signs of corrosion where the tyres press against the wheel rims,
◊
always use new valves on new tyres,
◊
protect the valves using seal equipped caps
Summary of Contents for VECTIS 1000