GB / IE - 1
5410.251.02
Part 1
Installation
ELECTRIC FRYERS
General Instructions
The appliance referred to in this manual has been
manufactured in conformity to the following Directives:
73/23/EEC, 93/68/EEC “Low Voltage”; 89/336/EEC,
92/31/EEC, 93/68/EEC and EN55014 “Electromagnetic
Compatibility.
The appliance must be installed by a qualified technician
according to the regulations and directives in force in the
country where it is installed, as well as the instructions in this
manual.
This appliance has been designed exclusively for cooking
food.
Remove the packaging from the appliance as well as the
protective plastic sheet, and, if necessary, remove traces of
glue with a suitable solvent.
To dispose of the packaging, follow local directives.
When installing the appliance, the following regulations must
be observed:
•
Applicable national laws in force;
•
Regional and/or local regulations, such as building
codes;
•
Directives and regulations of the local electricity board;
•
Accident prevention regulations in force;
•
Fire prevention regulations;
•
Applicable I.E.C. regulations.
To use the appliance correctly follow the warnings below:
•
The appliance must never be left unattended when it is
being used!
•
The appliance is designed for professional use and
therefore should only be used by qualified personnel.
•
Care must be taken when using the appliance because
the cooking surfaces are very hot.
•
The appliance should be installed under an extractor fan
for removing cooking fumes.
If the appliance is installed in line:
•
Respect a minimum distance of 80mm between the
appliance and any walls made of flammable material,
partitions, kitchen furniture or nearby equipment.
•
The contact surfaces must be covered with non-
combustible heat insulating material.
•
The appliance, and especially the power lead, must not
be installed anywhere near heat sources.
•
The temperature of the environment in which the
appliance is installed must not rise above 50°C.
WARNING!
Switch the appliance off in the case of a failure or malfunction.
Connection to the distribution network
Before connecting the appliance note the specifications
necessary for the installation: voltage, frequency, number of
phases and power on the data plate of the appliance.
The self-adhesive polyester data plate is behind the control
panel.
The installer must make the connection after having
installed a main switch, which is easy to reach and
disconnects every pole supplying electrical power to the
appliance.
The switch supplying electrical energy to the appliance must
have a minimum distance of at least 3 mm between the poles
when the contacts are open.
THE CABLE:
•
Must not be installed near heat sources, the ambient
temperature of the surrounding environment must not
rise to over 50°C.
•
Must be protected by a rigid metal or plastic tube
•
Must at least meet H07 RN-F standards.
•
Must have the minimum section indicated in the table
(fig.1).
To reach terminal board “M” (fig.2 and 3), remove the control
panel by loosening the screws on the lower part of the panel.
Following the indications in the wiring diagram, connect the
wires of the power cable to the terminal board.
The appliance must be connected to a good earth. There is a
screw marked with the symbol
:
near the terminal board
where the earth conductor should be connected.
Make sure you slide the cable through the relevant hole "P"
(fig.2) near the terminal board, hold the cable in place until
you can block it with cable clamp “AL” (fig.2 and 3).
The appliance must be connected to a good earth.
The appliance must also be connected to an
equipotential earth. Connect the earth with the screw marked
9
on the rear panel of the appliance in model FRE and on
the bottom in model FRS.
The equipotential wire must have a section of 10 mm
2
.