CONNECTION TO WATERWORKS
-
Water inlet pressure must be between 50 and 300 kPa, otherwise install a pressure regulator on the line before the appliance.
-
Install a cut-off valve for each supply on the line before the appliance.
-
Make connections according to regulations currently in force.
COMMISSIONING AND TESTING
-
Once all the connections have been made, the appliance and the overall installation must be checked following the directions given in this
manual.
-
Check in particular:
-
that the protective film has been removed from the external surfaces;
-
that the terminal board housing, removed for electrical connections, has been reinstalled.
-
that connections have been made in accordance with the requirements and directions indicated in this manual;
-
that all safety requirements in current standards, statutory regulations and directives have been met;
-
that the water connections are leak-free;
-
that the electrical connection has been performed according to standards.
-
In addition, check that once the appliance has been installed, the power cord is neither subject to stretch nor in contact with nor surfaces.
-
Now proceed to light the appliance as directed in the instructions for use.
-
While the appliance is in use, voltage should not differ from the nominal voltage more than +/- 10%.
-
The test report must be completed in full and submitted to the customer who should then sign in acceptance. With effect from this moment, the
appliance is covered by the manufacturer’s warranty.
MAINTENANCE OF THE APPLIANCE
-
All maintenance operations shall only be performed by a technically qualified service centre!
-
To ensure correct and safe operation, the appliance must be inspected and serviced at least once a year only. Maintenance includes also to
control the components and tear of pipes, feeding pipes, electrical components etc..
-
It is advisable to replace worn components during maintenance operations to avoid the need for other maintenance calls and unexpected
failures.
-
It is also advisable to apply for a maintenance contract with the customer.
POSSIBLE FAILURES AND THEIR ELIMINATION
-
Only technically qualified service centres can perform the operations described below!
-
Before resetting the safety thermostat, it is always necessary to eliminate the problem causing its activation!
-
Even a normal use of the appliance may cause operation inconveniences and failures.
THE MOST COMMON PROBLEMS ARE THE FOLLOWING:
P
AN DOES NOT REACH SET TEMPERATURE
:
Possible causes:
- Check connections to the switch.
- Check connection to the working thermostat.
- Check connection to electromagnetic switch.
- Heating elements are burned.
S
IGNAL LAMPS DO NOT LIGHT UP
- Check the connection to the switch.
- Signal lamp is faulty.
THE BRATT PAN WORKS WITH DISCONNECTED THEMOSTAT
-
Electromagnetic switch contacts are cut off.
L
OW EFFICIENTY OF THE PAN
- Check the heating elements.