Access level 1
Technical prealarm
Control panel 1
Hotel Aurora
Administration
Zone 1
16/02/2019
08:00:00
16/02/2019
08:00:00
Access level 1
Technical alarm
Control panel 1
Hotel Aurora
Administration
Zone 1
16/02/2019
08:00:00
16/02/2019
08:00:00
Access level 1
Failure
Failure
Control panel 1
Hotel Aurora
Console 1
Communication missing
16/02/2019
08:00:00
N.B.
Since the control panel controls the zones, the failures and the alarms of the individual detectors and modules are not added
up in the count, but they are considered integral to the individual zones. Accordingly, for the events related to a zone, to the left of
the cursor a number is displayed, indicating how many detectors and/or modules of the zone are affected by the event.
Selecting the event with the cursor and pressing the
OK
key the view of the zone is expanded showing the detail of the devices.
TECHNICAL PRELARM STATE
A technical double-knock zone in alarm or a detector in prealarm state.
Signaling before
acknowledgment
The speaker issues the audible prealarm signal
The
TECHNICAL ALARM
LED
fl
ashes
The output programmed for technical prealarm is triggered
The display shows the technical prealarm state
Signaling after the
fi
rst
acknowledgment
The speaker is muted
The
TECHNICAL ALARM
LED turns on steadily
The display shows the list of active technical alarms
Signaling after the second
acknowledgment
The speaker issues the list of technical zones in prealarm state
TECHNICAL ALARM STATE
A technical single-knock zone in alarm, or multiple detectors of a technical double-knock zone in alarm.
Signaling before
acknowledgment
The speaker issues the audible alarm signal
The
TECHNICAL ALARM
LED
fl
ashes
The output programmed for technical alarm is triggered
The display shows the technical alarm state
Signaling after the
fi
rst
acknowledgment
The speaker is muted
The
TECHNICAL ALARM
LED turns on steadily
The display shows the list of active technical alarms
Signaling after the second
acknowledgment
In case of a zone alarm, the display shows the associated
alarm plan.
FAILURE STATE
Zone failure or system failure.
Signaling before
acknowledgment
The speaker issues the audible failure signal
The
GENERAL FAILURE
LED
fl
ashes
The failure relay is activated
The display shows the failure state
Signaling after the
fi
rst
acknowledgment
The speaker is muted
The
GENERAL FAILURE
LED turns on steadily
The display shows the list of active failures
Signaling after the second
acknowledgment
The speaker issues the list of failures
Summary of Contents for Tecnofire TFA2-596
Page 2: ...TFA2 596 TFA4 1192 2...
Page 4: ...TFA2 596 TFA4 1192 4...
Page 10: ...TFA2 596 TFA4 1192 10...
Page 14: ...TFA2 596 TFA4 1192 14...
Page 28: ...TFA2 596 TFA4 1192 28...
Page 32: ...TFA2 596 TFA4 1192 32...
Page 40: ...TFA2 596 TFA4 1192 40...
Page 50: ...TFA2 596 TFA4 1192 50...
Page 62: ...TFA2 596 TFA4 1192 62 NOTES...
Page 63: ......