Configuring converters / MasterCAN RS2CAN configuration for data conversion from Modbus RTU registers into SPN
MasterCAN RS2CAN / CAN2RS data converters. Operation manual. Version 1.0
©
Technoton, 2020
38
•
The field
S6 Address (SA)
) serves to specify the unique network address
CAN j1939/S6 Telematics interface
which the request for reading the selected SPN is needed. The network address may be
specified from 0…250 range (by default —
134
).
•
The field
PGN Sendings Period
) serves to specify the output order of
the message (
) containing SPN with the converted data into CAN output interface
by the converter. Depending on the selected SPN, the value of the period is entered
automatically, in accordance with
The period of sending may be changed for
the value from 0…30000 range
(0 value indicates that the selected SPN is read upon request, other value indicates the
interval (in milliseconds) of automatic output of PGN containing the selected SPN into
CAN-bus).
Figure 23
—
Example of configured slots for conversion of data from Modbus RTU registers into SPN
In order to copy the settings of the slot created earlier into the new slot, tick the field to the
left from the number of the slot which is to be copied and press
button. For this
operation, you may highlight only one slot for copying (see figure 23).
To delete one specific slot, use
button, to the right of its settings. To delete all created
slots, press
button.
In Service S6 MasterCAN software for each SPN, whenever you place the cursor on its name,
prompts containing its number, data range etc. are displayed. The automatic control of
correctness of values entered is provided in the fields for editing settings. The corresponding
prompts appear, whenever you place the cursor on the field with the value to be edited.
During work with
MODBUS-CAN Gate FM
of
MasterCAN RS2CAN
converter the software
). The list of SPN of
MasterCAN RS2CAN
FM which are configured and/or displayed using the software is provided in
To update S6 Database in Service S6 MasterCAN software, press
in the
dropdown menu
. The detailed description of S6 Database can be found at